DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol
SNMP (MIB)
MN-DMDREMOTEOP Revision 9
2–54
-- DMD20 LBST
-- Dmd20 Mod Lbst nonvolatile status information.
radDmd20LbstTxUplinkFrequencyHz OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects RF frequency in Hz steps. 2GHz to 99 GHz."
::= { radDmd20ModLbstNVStatus 1 }
radDmd20LbstTxLoFrequencyHz OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects local oscillator frequency in Hz steps. 2GHz to 99 GHz."
::= { radDmd20ModLbstNVStatus 2 }
radDmd20LbstTxSideBand OBJECT-TYPE
SYNTAX INTEGER {
highSide(1),
lowSide(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Oscillator side band select."
::= { radDmd20ModLbstNVStatus 3 }
radDmd20LbstTx10MhzReferenceEnable OBJECT-TYPE
SYNTAX ControlType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"10 MHz BUC reference enable."
::= { radDmd20ModLbstNVStatus 4 }
radDmd20LbstTxVoltageEnable OBJECT-TYPE
SYNTAX ControlType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"BUC supply voltage enable."
::= { radDmd20ModLbstNVStatus 5 }
radDmd20LbstTxVoltageLowerThreshold OBJECT-TYPE
SYNTAX RadVoltageLevel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"BUC low voltage alarm threshold. There is an implied decimal point."
::= { radDmd20ModLbstNVStatus 6 }
radDmd20LbstTxVoltageUpperThreshold OBJECT-TYPE
SYNTAX RadVoltageLevel