beautypg.com

Comtech EF Data DMD20 User Manual

Page 93

background image

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol

Remote Operations

MN-DMDREMOTEOP Revision 9

1–83

Opcode: <2500h>

Command Up Converter Configuration

Command Data (15 Bytes)

<8> LO

Frequency

Hz

<1>

Mix Select

0 = High side, 1 = Low side

<1>

Reference Enable

0 = Disabled, 1 = Enabled

<1> Supply

Voltage

Enable

0 = Disabled, 1 = Enabled

<1> FSK

Communications

Select

0 = None, 1 = Codan, 2 = TerraSat, 3 = Amplus

<2> BUC

Address

<1>

BUC Output Enable

0 = Disabled, 1 = Enabled


Opcode: <2501h>

Command Uplink RF

Command Data (8 Bytes)

<8> RF

Hz


Opcode: <2502h>

Command Down Converter Configuration

Command Data (12 Bytes)

<8> LO

Frequency

Hz

<1>

Mix Select

0 = High side, 1 = Low side

<1>

Reference Enable

0 = Disabled, 1 = Enabled

<1> Supply

Voltage

Enable

0 = Disabled, 1 = Enabled

<1> Supply

Voltage

Select

13, 16, 18, 24, 48


Opcode: <2503h>

Command Downlink RF

Command Data (8 Bytes)

<8> RF

Hz


Opcode: <2F61h>

Command BUC FSK Pass Thru

Command Data (64 Bytes)

<64> BUC FSK Command

Data

Null Terminated ASCII string


Opcode: <2E06h>

Query BUC FSK Pass thru Reply

Query Response (255 Bytes)

<255>

BUC FSK Reply Data

Null Terminated ASCII string

The following opcode is for customer purchased and installed features only.


Opcode: <2450h>

Query a Module's Installed Features (Customer Purchased)

This manual is related to the following products: