Comtech EF Data DMD20 User Manual
Page 93

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol
Remote Operations
MN-DMDREMOTEOP Revision 9
1–83
Opcode: <2500h>
Command Up Converter Configuration
Command Data (15 Bytes)
<8> LO
Frequency
Hz
<1>
Mix Select
0 = High side, 1 = Low side
<1>
Reference Enable
0 = Disabled, 1 = Enabled
<1> Supply
Voltage
Enable
0 = Disabled, 1 = Enabled
<1> FSK
Communications
Select
0 = None, 1 = Codan, 2 = TerraSat, 3 = Amplus
<2> BUC
Address
<1>
BUC Output Enable
0 = Disabled, 1 = Enabled
Opcode: <2501h>
Command Uplink RF
Command Data (8 Bytes)
<8> RF
Hz
Opcode: <2502h>
Command Down Converter Configuration
Command Data (12 Bytes)
<8> LO
Frequency
Hz
<1>
Mix Select
0 = High side, 1 = Low side
<1>
Reference Enable
0 = Disabled, 1 = Enabled
<1> Supply
Voltage
Enable
0 = Disabled, 1 = Enabled
<1> Supply
Voltage
Select
13, 16, 18, 24, 48
Opcode: <2503h>
Command Downlink RF
Command Data (8 Bytes)
<8> RF
Hz
Opcode: <2F61h>
Command BUC FSK Pass Thru
Command Data (64 Bytes)
<64> BUC FSK Command
Data
Null Terminated ASCII string
Opcode: <2E06h>
Query BUC FSK Pass thru Reply
Query Response (255 Bytes)
<255>
BUC FSK Reply Data
Null Terminated ASCII string
The following opcode is for customer purchased and installed features only.
Opcode: <2450h>
Query a Module's Installed Features (Customer Purchased)