beautypg.com

Comtech EF Data DMD20 User Manual

Page 151

background image

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol

SNMP (MIB)

MN-DMDREMOTEOP Revision 9

2–55

MAX-ACCESS read-write
STATUS current
DESCRIPTION
"BUC Hi voltage alarm threshold. There is an implied decimal point."
::= { radDmd20ModLbstNVStatus 7 }

radDmd20LbstTxCurrentLowerThreshold OBJECT-TYPE
SYNTAX RadCurrentLevel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"BUC Low current draw alarm threshold. There is an implied decimal point."
::= { radDmd20ModLbstNVStatus 8 }

radDmd20LbstTxCurrentUpperThreshold OBJECT-TYPE
SYNTAX RadCurrentLevel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"BUC Hi current draw alarm threshold. There is an implied decimal point."
::= { radDmd20ModLbstNVStatus 9 }

radDmd20FskCommsSelect OBJECT-TYPE
SYNTAX INTEGER {
commsSelectNone(1),
commsSelectCodan(2),
commsSelectTerraSat(3),
commsSelectAmplus(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the protocol used on the Fsk port"
::= { radDmd20ModLbstNVStatus 10 }

radDmd20FskTestType OBJECT-TYPE
SYNTAX INTEGER {
fskTestTypeNone(1),
fskTestTypeLoopback(2),
fskTestTypeCycleTxEnable(3),
fskTestTypeCodanPassThru(4),
fskTestTypeTerrasatPassThru(5),
fskTestTypeAmplusPassThru(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the type of Fsk communications test to use"
::= { radDmd20ModLbstNVStatus 11 }

radDmd20BucAddress OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Address used when when Fsk messages are sent to the Buc. This address

This manual is related to the following products: