Comtech EF Data DMD20 User Manual
Page 92

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol
Remote Operations
MN-DMDREMOTEOP Revision 9
1–82
Opcode: <2C09h>
Clear Modem Common Latched Alarm 2 (No Data)
Command Data (0 Bytes)
Opcode: <2C0Ah>
Command Delete a Modem's Event Buffer
Command Data (1 Byte)
<1>
Events to Delete
1 = delete one event (deletes first event in buffer) , 2 =
delete all events
Opcode: <2C0Bh>
Command Soft Reset (No Data) (Stops petting the watch dog to restart the
processor)
Command Data (0 Bytes)
Opcode: <2490h>
Query Up Converter Configuration
Query Response (22 Bytes)
<8> LO
Frequency
Hz
<1>
Mix Select
0 = High side, 1 = Low side
<1>
Reference Enable
0 = Disabled, 1 = Enabled
<1> Supply
Voltage
Enable
0 = Disabled, 1 = Enabled
<1> FSK
Communications
Select
0 = None, 1 = Codan, 2 = TerraSat, 3 = Amplus
<2> BUC
Address
<1>
BUC Output Enable
0 = Disabled, 1 = Enabled
<2>
BUC Carrier Level
Implied decimal point, dBm
<4> BUC
Summary
Status
<1>
BUC Temperature
Degrees, C
Opcode: <2491h>
Query Uplink RF
Query Response (8 Bytes)
<8> RF
Hz
Opcode: <2492h>
Query Down Converter Configuration
Query Response (12 Bytes)
<8> LO
Frequency
Hz
<1>
Mix Select
0 = High side, 1 = Low side
<1>
Reference Enable
0 = Disabled, 1 = Enabled
<1> Supply
Voltage
Enable
0 = Disabled, 1 = Enabled
<1> Supply
Voltage
Select
13, 16, 18, 24, 48
Opcode: <2493h>
Query Downlink RF
Query Response (8 Bytes)
<8> RF
Hz