Comtech EF Data DMD20 User Manual
Page 22
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol
Remote Operations
MN-DMDREMOTEOP Revision 9
1–12
When new features are added to Radyne equipment, the control parameters
are appended to the end of the Non-Volatile Section of the Remote
Communications Specification, and status of the features, if any, are added at
the end of the Volatile Section. If a remote M & C queries two pieces of Radyne
equipment with different revision software, they could respond with two
different sized packets. The remote M & C MUST make use of the non-volatile
count value to index to the start of the Volatile Section. If the remote M & C is
not aware of the newly added features to the product, it should disregard the
parameters at the end of the Non-Volatile Section and index to the start of the
Volatile Section.
Before creating any software based on the information contained in this
document, contact the Comtech EF Data Customer Service Department (480-
333-4357) to find out if the software revision for that piece of equipment is
current and that no new features have been added since the release of this
document.
1.4.1
Modem Command Set:
Command
Opcode
Query Modulator Configuration and Status
2400h
Query Demodulator Configuration and Status
2401h
Query Modem Drop & Insert Map
2402h
Query Modems Identification
2403h
Query Modem Control Mode
2404h
Query Modulator Latched Alarms
2405h
Query Demodulator Latched Alarms
2406h
Query Modem Latched Alarms
2407h
Query Modulator Current Alarms
2408h
Query Demodulator Current Alarms
2409h
Query Modem Current Alarms
240Ah
Query Modulator Status
240Bh
Query Demodulator Status
240Ch
Query Modem Eb/No, BER and Level
240Dh
Query Time
240Eh
Query Date
240Fh
Query Time and Date
2410h
Query Modem Summary Faults
2411h
Query Modem Event Buffer
2412h
Query Modulator Configuration
2448h
Query Demodulator Configuration
2449h
Query Modem Features
2450h
Query Modulator Async Configuration
2451h
Query Demodulator Async Configuration
2452h
Query Up converter Configuration
2490h
Query Uplink RF
2491h
Query Down converter Configuration
2492h
Query Downlink RF
2493h
Query Demodulator Ethernet Terrestrial Interface Packet Status
2494h