DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol

Remote Operations

MN-DMDREMOTEOP Revision 9

1–73

<1>

Rx Interface Type

0 = G.703 Bal T1 AMI, 1 = G.703 Bal T1 B8ZS, 2 =
G.703 B E1 HDB3, 3 = G.703 Bal T2 B6ZS, 4 = G.703
Unbal E1 HDB3, 5 = G.703 Unbal T2 B8ZS, 6 = G.703
Unbal E2 HDB3, 7 = RS422 Serial, 8 = V.35, 9 =
RS232 Serial, 10 = HSSI, 11 = ASI, 12 = Advanced
ASI, 13 = M2P Parallel, 14 = DVB Parallel, 24 =
Ethernet Bridge, 25 = MIL-188-114A, 26 = RS423
Serial, 27 = Eurocomm 256, 28= Eurocomm 512, 29 =
Eurocomm 1024, 30 = Eurocomm 2048, 31 = G.703
Unbal T3 B3ZS, 32 = G.703 Unbal E3 HDB3, 33 =
G.703 Unbal STS1 HDB3


Opcode: <2A20h>

Command Center Buffer (No Parameters)

Command Data (0 Bytes)


Opcode: <2A21h>

Command a Demodulator’s Data Invert

Command Data (1 Byte)

<1>

Data Invert

0 = None, 1 = Terrestrial, 2 = Baseband, 3 = Terrestrial
and Baseband


Opcode: <2A22h>

Command Force Demodulator Alarm Test

Command Data (1 Byte)

<1>

Force Alarm Test

Bit 0 = Rx Major Alarm
Bits 1 – 7 = Spares
0 = Do not force, 1 = Force


Opcode: <2A23h>

Command External EXC Source

Command Data (1 Byte)

<1>

External EXC Source

Reserved


Opcode: <2A24h>

Clear Demodulator Latched Alarm 1 (No Data)

Command Data (0 Bytes)


Opcode: <2A25h>

Clear Demodulator Latched Alarm 2 (No Data)

Command Data (0 Bytes)


Opcode: <2A26h>

Clear Demodulator Latched Alarm 3 (No Data)

Command Data (0 Bytes)


Opcode: <2A2Fh>

Command Demodulator Reacquisition Boundary

Command Data (2 Bytes)

<2> Reacquisition

Sweep

Limit

Binary value, 1 Hz steps, 0 – 65535


Opcode: <2A32h> Command a demodulator’s Reed Solomon N & K Codes and Interleaver Depth