<1> Tx

Terrestrial

Loopback

0 = Disabled, 1 = Enabled

<1> Tx

Baseband

Loopback

0 = Disabled, 1 = Enabled

<1>

Drop Status Mask

Bit 0 = Frame lock fault
Bit 1 = Multiframe lock Fault. Valid in E1 PCM-30 and

PCM-30C

Bit 2 = CRC lock fault. Valid in T1ESF, and E1 CRC

enabled

Bits 3 – 7 = Reserved
0 = Mask, 1 = Allow

<1>

Tx RS N Code

2 – 255, Reed-Solomon code word length

<1>

Tx RS K Code

1 – 254, Reed-Solomon message length

<1>

Tx RS Depth

4, 8, or 12

<1>

Data Invert

0 = None, 1 = Terrestrial, 2 = Baseband, 3 = Terrestrial
and Baseband

<1>

BPSK Symbol Pairing 0 = Normal Pairing, 1 = Swapped Pairing

<1>

IDR Overhead Type

0 = 32K Voice, 1 = 64K Data

<1>

Terminal Emulation

0 = Adds Viewpoint, 1 = VT100, 2 = WYSE50

<1>

Terminal Baud Rate

0 = 300, 1 = 600, 2 = 1200, 3 = 2400, 4 = 4800, 5 =
9600, 6 = 19200, 7 = 38400, 8 = 57600, 9 = 1152000,
10 = 150

<1>

FM Orderwire Mode

Reserved

<1>

FM Orderwire Test
Tone

Reserved

<1>

AUPC Local Enable

0 = Off, 1 = EF AUPC, 2 = Radyne AUPC

<1> AUPC

Remote

Enable

0 = Off, 1 = EF AUPC

<1> AUPC

Local

CL

Action

0 = Hold, 1 = Nominal, 2 = Maximum

<1>

AUPC Remote CL
Action

0 = Hold, 1 = Nominal, 2 = Maximum

<1>

AUPC Tracking Rate

0 = 0.5 dB/Min, 1 = 1.0 dB/Min, 2 = 1.5 dB/Min, 3 = 2.0
dB/Min, 4 = 2.5 dB/Min, 5 = 3.0 dB/Min, 6 = 3.5 dB/Min,
7 = 4.0 dB/Min, 8 = 4.5 dB/Min, 9 = 5.0 dB/Min, 10 =
5.5 dB/Min, 11 = 6.0 dB/min

<1>

AUPC Remote BB
Loopback

0 = Disabled, 1 = Enabled

<1>

AUPC Remote 2047

0 = Disabled, 1 = Enabled

<2>

AUPC Target Eb/No

Target Eb/No at Receiver, 400 to 2000 (4.00 db to
20.00 db)

<2> AUPC

Minimum

Power

For DMD20 Signed value 0 to –2500 with implied
decimal point; (0.00 to –25.00 dBm) (two’s compliment)
For OM20 Signed value -2000 to -4500 with implied
decimal point; (-20.00 to -45.00 dBm)

<2> AUPC

Maximum

Power

For DMD20 Signed value 0 to –2500 with implied
decimal point; (0.00 to –25.00 dBm) (two’s compliment)
For OM20 Signed value -2000 to -4500 with implied
decimal point; (-20.00 to -45.00 dBm)

<2> AUPC

Nominal

Power

For DMD20 Signed value 0 to –2500 with implied
decimal point; (0.00 to –25.00 dBm) (two’s compliment)
For OM20 Signed value -2000 to -4500 with implied
decimal point; (-20.00 to -45.00 dBm)

<1> TMT

Pattern

Enable Reserved

<1> TMT

Pattern

Length Reserved