DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol

SNMP (MIB)

MN-DMDREMOTEOP Revision 9

2–31

"Selects the data bits setting for enhanced async. This applies only if the async
mode is set to enhanced."
::= { radDmd20DemodNVStatus 33 }

radDmd20RxTestPattern OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
test2047(2),
testPattern2To15Minus1(3),
testPattern2To23Minus1(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables test pattern operation."
::= { radDmd20DemodNVStatus 34 }

radDmd20RxCircuitName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (11))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Provides entry of Rx circuit identifier. Circuits can be given up to 11
character alphanumeric identity such as LINK1."
::= { radDmd20DemodNVStatus 35 }

radDmd20RxForcedAlarms OBJECT-TYPE
SYNTAX BITS {
forceSummaryAlarm(0)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Rx forced alarms:
0=Do not force, 1=Force alarm
This alarm was improperly titled and is being deprecated, use
radDmd20RxForceAlarmTest in future"
::= { radDmd20DemodNVStatus 36 }

radDmd20RxAlarms1Mask OBJECT-TYPE
SYNTAX BITS {
rxFpgaFault(0),
carrierFault(1),
multiframeSyncFault(2),
frameSyncFault(3),
ibsBerFault(4),
satelliteAisFault(5),
dataActivity(6),
agcLevelFault(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Alarm mask:
0 = Mask, 1 = Allow"
::= { radDmd20DemodNVStatus 37 }