Comtech EF Data DMD20 User Manual
Page 29

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol
Remote Operations
MN-DMDREMOTEOP Revision 9
1–19
<1>
Terrestrial Framing
0 = DVB 188, 1 = DVB 204, 2 = NONE
<1>
Alarm 4 Mask
Bit 0 = LBST BUC DC Current Alarm
Bit 1 = LBST BUC DC Voltage Alarm
Bit 2 = Ethernet WAN Alarm
Bit 3 = LBST BUC PLL Alarm
Bit 4 = LBST BUC Over Temperature Alarm
Bit 5 = LBST BUC Summary Alarm
Bit 6 = LBST BUC Output Enable Alarm
Bit 7 = LBST BUC Communications Alarm
0 = Mask, 1 = Allow
<1>
TPC Interleaver
0 = Disabled, 1 = Enabled
<1>
Ethernet Flow Control 0 = Disabled, 1 = Enabled
<1>
Ethernet Daisy Chain
0 = Disabled, 1 = Enabled (Port 4)
<1>
ES Mode
0 = Normal, 1 = Enhanced
<1>
ES Type
0 = RS232, 1 = RS485
<1>
ES Baud Rate
0 =150, 1 = 300, 2 = 600, 3 = 1200, 4 = 2400, 5= 4800,
6 = 9600, 7 = 19200, 8 = 38400, 9 = 57600, 10 =
115200
<1>
ES Data Bits
0 = 7 bits, 1 = 8 bits
<1>
Carrier Enable Delay
0 – 255 in seconds
<1>
SCC Control Ratio
1 = 1/1, 2 = 1/2, 3 = 1/3, 4 = 1/4, 5 = 1/5, 6 = 1/6, 7 =
1/7
<4>
SCC In band Rate
300 to 200000 bps
<2>
LBST BUC DC
Voltage Alarm Lower
Threshold
Volts, Implied decimal point, 10 = 1.0V (00.0 V to 55.0
V)
<2>
LBST BUC DC
Voltage Alarm Upper
Threshold
Volts, Implied decimal point, 10 = 1.0V (00.0 V to 55.0
V)
<2>
LBST BUC DC
Current Alarm Lower
Threshold
Amps, Implied decimal point, 1000 = 1.000A (0.000 A
to 8.000 A)
<2>
LBST BUC DC
Current Alarm Upper
Threshold
Amps, Implied decimal point, 1000 = 1.000A (0.000 A
to 8.000 A)
<2>
Compensation
TX Power Level offset from 0 to 10 (0.0 dBm to 1.0
dBm), Implied decimal point
<1>
Forced Alarm Test
Bit 0 = Tx Major Alarm
Bits 1 – 7 = Spares
0 = Not Forced, 1 = Forced
<1> Asynchronous
In-
Band Rate
0 =150, 1 = 300, 2 = 600, 3 = 1200, 4 = 2400, 5= 4800,
6 = 9600, 7 = 19200, 8 = 38400, 9 = 57600, 10 =
115200
<1> FSK
Communications
Select
0 = None, 1 = Codan, 2 = TerraSat, 3 = Amplus
<1>
FSK Test Type
0 = None, 1 = Loopback, 2 = Cycle TX Enable, 3 =
Codan Pass thru, 4 = TerraSat pass thru, 5 = Amplus
Pass thru, 6 = Query for address
<2> BUC
Address
<1>
BUC Output Enable
0 = Disabled, 1 = Enabled
<1>
Minor Alarm Relay
Usage
0 = undefined, 1= IBS Usage, 2 = IBS & Minor Alarms,
3 = IBS, Minor Alarms and Major Alarms
<1>
Ethernet QOS Type
0 = Normal, 1 = Port based
<1> Ethernet
QOS
QUEUE
0 = Fair Weighted, 1 = Strict Priority