DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol

Remote Operations

MN-DMDREMOTEOP Revision 9

1–19

<1>

Terrestrial Framing

0 = DVB 188, 1 = DVB 204, 2 = NONE

<1>

Alarm 4 Mask

Bit 0 = LBST BUC DC Current Alarm
Bit 1 = LBST BUC DC Voltage Alarm
Bit 2 = Ethernet WAN Alarm
Bit 3 = LBST BUC PLL Alarm
Bit 4 = LBST BUC Over Temperature Alarm
Bit 5 = LBST BUC Summary Alarm
Bit 6 = LBST BUC Output Enable Alarm
Bit 7 = LBST BUC Communications Alarm
0 = Mask, 1 = Allow

<1>

TPC Interleaver

0 = Disabled, 1 = Enabled

<1>

Ethernet Flow Control 0 = Disabled, 1 = Enabled

<1>

Ethernet Daisy Chain

0 = Disabled, 1 = Enabled (Port 4)

<1>

ES Mode

0 = Normal, 1 = Enhanced

<1>

ES Type

0 = RS232, 1 = RS485

<1>

ES Baud Rate

0 =150, 1 = 300, 2 = 600, 3 = 1200, 4 = 2400, 5= 4800,
6 = 9600, 7 = 19200, 8 = 38400, 9 = 57600, 10 =
115200

<1>

ES Data Bits

0 = 7 bits, 1 = 8 bits

<1>

Carrier Enable Delay

0 – 255 in seconds

<1>

SCC Control Ratio

1 = 1/1, 2 = 1/2, 3 = 1/3, 4 = 1/4, 5 = 1/5, 6 = 1/6, 7 =
1/7

<4>

SCC In band Rate

300 to 200000 bps

<2>

LBST BUC DC
Voltage Alarm Lower
Threshold

Volts, Implied decimal point, 10 = 1.0V (00.0 V to 55.0
V)

<2>

LBST BUC DC
Voltage Alarm Upper
Threshold

Volts, Implied decimal point, 10 = 1.0V (00.0 V to 55.0
V)

<2>

LBST BUC DC
Current Alarm Lower
Threshold

Amps, Implied decimal point, 1000 = 1.000A (0.000 A
to 8.000 A)

<2>

LBST BUC DC
Current Alarm Upper
Threshold

Amps, Implied decimal point, 1000 = 1.000A (0.000 A
to 8.000 A)

<2>

Compensation

TX Power Level offset from 0 to 10 (0.0 dBm to 1.0
dBm), Implied decimal point

<1>

Forced Alarm Test

Bit 0 = Tx Major Alarm
Bits 1 – 7 = Spares
0 = Not Forced, 1 = Forced

<1> Asynchronous

In-

Band Rate

0 =150, 1 = 300, 2 = 600, 3 = 1200, 4 = 2400, 5= 4800,
6 = 9600, 7 = 19200, 8 = 38400, 9 = 57600, 10 =
115200

<1> FSK

Communications

Select

0 = None, 1 = Codan, 2 = TerraSat, 3 = Amplus

<1>

FSK Test Type

0 = None, 1 = Loopback, 2 = Cycle TX Enable, 3 =
Codan Pass thru, 4 = TerraSat pass thru, 5 = Amplus
Pass thru, 6 = Query for address

<2> BUC

Address

<1>

BUC Output Enable

0 = Disabled, 1 = Enabled

<1>

Minor Alarm Relay
Usage

0 = undefined, 1= IBS Usage, 2 = IBS & Minor Alarms,
3 = IBS, Minor Alarms and Major Alarms

<1>

Ethernet QOS Type

0 = Normal, 1 = Port based

<1> Ethernet

QOS

QUEUE

0 = Fair Weighted, 1 = Strict Priority