DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol

SNMP (MIB)

MN-DMDREMOTEOP Revision 9

2–43


radDmd20RxBufferLevel OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pleisiochronous buffer percent full status. Unsigned binary value in 1% steps."
::= { radDmd20DemodStatus 15 }

radDmd20RxCarrierLeveldBmX100 OBJECT-TYPE
SYNTAX RadReceivePowerLevel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Estimated receive signal level, implied decimal point"
::= { radDmd20DemodStatus 16 }

radDmd20RxBitErrorCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows the number of errors detected in the data stream"
::= { radDmd20DemodStatus 17 }

radDmd20RxTestPatternErrorCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows the number of errors detected by the test pattern checker."
::= { radDmd20DemodStatus 18 }

radDmd20RxLossOfTerrInputSignal OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
lossOfSignal(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of terrestrial input"
::= { radDmd20DemodStatus 19 }

radDmd20RxSymbolRateHz OBJECT-TYPE
SYNTAX Unsigned32 (9600..10000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Demodulator symbol rate."
::= { radDmd20DemodStatus 20 }

radDmd20RxAlarms6 OBJECT-TYPE
SYNTAX BITS {
lnbCurrentFault(0),
lnbVoltageFault(1),

This manual is related to the following products: