beautypg.com

Comtech EF Data DMD20 User Manual

Page 152

background image

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol

SNMP (MIB)

MN-DMDREMOTEOP Revision 9

2–56

is dependent upon the protocol selected. Some BUCs require specific values"
::= { radDmd20ModLbstNVStatus 12 }

radDmd20BucOutputEnable OBJECT-TYPE
SYNTAX ControlType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Using the Fsk interface and active Fsk protocol enable/disables the BUC output"
::= { radDmd20ModLbstNVStatus 13 }

-- ----------------------------------------------------------------------------------------------------
-- Dmd20 Mod Lbst volatile status information.

radDmd20LbstTxBucVoltageX10 OBJECT-TYPE
SYNTAX RadVoltageLevel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BUC voltage. Implied decimal point, 482 means 48.2Volts"
::= { radDmd20ModLbstStatus 1 }

radDmd20LbstTxBucCurrentX1000 OBJECT-TYPE
SYNTAX RadCurrentLevel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BUC current. Implied decimal point, 5500 means 5.500Amps"
::= { radDmd20ModLbstStatus 2 }


radDmd20FskTestResultAlarm OBJECT-TYPE
SYNTAX INTEGER {
testPass(1),
testFail(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the last Fsk Test"
::= { radDmd20ModLbstStatus 3 }

radDmd20BucCarrierLeveldBmX100 OBJECT-TYPE
SYNTAX RadTransmitPowerLevel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Tx power level of the BUC in dBm. There is an implied decimal point.
For example, a value of -100 represents a transmit power level
of -10.0 dBm."
::= { radDmd20ModLbstStatus 4 }

radDmd20BucSummaryStatus OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current

This manual is related to the following products: