Comtech EF Data DMD20 User Manual
Page 118

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol
SNMP (MIB)
MN-DMDREMOTEOP Revision 9
2–22
SYNTAX BITS {
terrClockActivity(0),
internalClockActivity(1),
satClockActivity(2),
dataActivity(3),
dataAISFault(4),
clockFallbackFault(5),
dvbFrameFault(6),
tpcConflict(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to the value '00000000'B.
0 = Pass, 1 = Fail"
::= { radDmd20ModStatus 6 }
radDmd20TxSymbolRateHz OBJECT-TYPE
SYNTAX Unsigned32 (9600..10000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator symbol rate"
::= { radDmd20ModStatus 7 }
radDmd20TxAlarms4 OBJECT-TYPE
SYNTAX BITS {
bucCurrentFault(0),
bucVoltageFault(1),
ethernetWanMajorAlarm(2),
bucPllAlarm(3),
bucOverTempAlarm(4),
bucSummaryAlarm(5),
bucOutputEnableAlarm(6),
bucCommunicationsAlarm(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to the value '00000000'B.
Activity/Lock: 1 = Pass, 0 = Fail
Alarm/Fault: 0 = Pass, 1 = Fail"
::= { radDmd20ModStatus 8 }
radDmd20TxLatchedAlarms4 OBJECT-TYPE
SYNTAX BITS {
bucCurrentFault(0),
bucVoltageFault(1),
ethernetWanMajorAlarm(2),
bucPllAlarm(3),
bucOverTempAlarm(4),
bucSummaryAlarm(5),
bucOutputEnableAlarm(6),
bucCommunicationsAlarm(7)
}
MAX-ACCESS read-only