Comtech EF Data DMD20 User Manual
Page 44

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol
Remote Operations
MN-DMDREMOTEOP Revision 9
1–34
<1>
Tx Interface Type
0 = G.703 Bal T1 AMI, 1 = G.703 Bal T1 B8ZS, 2 =
G.703 B E1 HDB3, 3 = G.703 Bal T2 B6ZS, 4 = G.703
Unbal E1 HDB3, 5 = G.703 Unbal T2 B8ZS, 6 = G.703
Unbal E2 HDB3, 7 = RS422 Serial, 8 = V.35, 9 =
RS232 Serial, 10 = HSSI, 11 = ASI, 12 = Advanced
ASI, 13 = M2P Parallel, 14 = DVB Parallel, 24 =
Ethernet Bridge, 25 = MIL-188-114A, 26 = RS423
Serial, 27 = Eurocomm 256, 28= Eurocomm 512, 29 =
Eurocomm 1024, 30 = Eurocomm 2048, 31 = G.703
Unbal T3 B3ZS, 32 = G.703 Unbal E3 HDB3, 33 =
G.703 Unbal STS1 HDB3
<1> Tx
Terrestrial
Loopback
0 = Disabled, 1 = Enabled
<1> Tx
Baseband
Loopback
0 = Disabled, 1 = Enabled
<1>
Drop Status Mask
Bit 0 = Frame lock fault
Bit 1 = Multiframe lock Fault. Valid in E1 PCM-30 and
PCM-30C
Bit 2 = CRC lock fault. Valid in T1ESF, and E1 CRC
enabled
Bits 3 – 7 = Reserved
0 = Mask, 1 = Allow
<1>
Tx RS N Code
2 – 255, Reed-Solomon code word length
<1>
Tx RS K Code
1 – 254, Reed-Solomon message length
<1>
Tx RS Depth
4, 8, or 12
<1>
Data Invert
0 = None, 1 = Terrestrial, 2 = Baseband, 3 = Terrestrial
and Baseband
<1>
BPSK Symbol Pairing 0 = Normal Pairing, 1 = Swapped Pairing
<1>
IDR Overhead Type
0 = 32K Voice, 1 = 64K Data
<1>
Terminal Emulation
0 = Adds Viewpoint, 1 = VT100, 2 = WYSE50
<1>
Terminal Baud Rate
0 = 300, 1 = 600, 2 = 1200, 3 = 2400, 4 = 4800, 5 =
9600, 6 = 19200, 7 = 38400, 8 = 57600, 9 = 1152000,
10 = 150
<1>
FM Orderwire Mode
Reserved
<1>
FM Orderwire Test
Tone
Reserved
<1>
AUPC Local Enable
0 = Off, 1 = EF AUPC, 2 = Radyne AUPC
<1> AUPC
Remote
Enable
0 = Off, 1 = EF AUPC
<1> AUPC
Local
CL
Action
0 = Hold, 1 = Nominal, 2 = Maximum
<1>
AUPC Remote CL
Action
0 = Hold, 1 = Nominal, 2 = Maximum
<1>
AUPC Tracking Rate
0 = 0.5 dB/Min, 1 = 1.0 dB/Min, 2 = 1.5 dB/Min, 3 = 2.0
dB/Min, 4 = 2.5 dB/Min, 5 = 3.0 dB/Min, 6 = 3.5 dB/Min,
7 = 4.0 dB/Min, 8 = 4.5 dB/Min, 9 = 5.0 dB/Min, 10 =
5.5 dB/Min, 11 = 6.0 dB/min
<1>
AUPC Remote BB
Loopback
0 = Disabled, 1 = Enabled
<1>
AUPC Remote 2047
0 = Disabled, 1 = Enabled
<2>
AUPC Target Eb/No
Target Eb/No at Receiver, 400 to 2000 (4.00 db to
20.00 db)