<11> Tx Circuit ID

11 ASCII characters, null terminated


Opcode: <2622h>

Command Force Modulator Alarm Test

Command Data (1 Byte)

<1>

Forced Alarm Test

Bit 0 = Tx Major Alarm
Bits 1 – 7 = Spares
0 = Not Forced, 1 = Forced


Opcode: <2623h>

Command Modulator Data Invert

Command Data (1 Byte)

<1>

Data Invert

0 = None, 1 = Terrestrial, 2 = Baseband, 3 = Terrestrial
and Baseband


Opcode: <2625h>

Clear a Modulator’s Latched Alarm 1 (No Data)

Command Data (0 Bytes)


Opcode: <2629h>

Command AUPC Local Enable

Command Data (1 Byte)

<1>

AUPC Local Enable

0 = Off, 1 = EF AUPC, 2 = Radyne AUPC


Opcode: <262Ah>

Command AUPC Remote Enable

Command Data (1 Byte)

<1> AUPC

Remote

Enable

0 = Off, 1 = EF AUPC


Opcode: <262Bh>

Command AUPC Local CL Action

Command Data (1 Byte)

<1> AUPC

Local

CL

Action

0 = Hold, 1 = Nominal, 2 = Maximum


Opcode: <262Ch>

Command AUPC Remote CL Action

Command Data (1 Byte)

<1>

AUPC Remote CL
Action

0 = Hold, 1 = Nominal, 2 = Maximum


Opcode: <262Dh>

Command AUPC Tracking Rate

Command Data (1 Byte)

<1>

AUPC Tracking Rate

0 = 0.5 dB/Min, 1 = 1.0 dB/Min, 2 = 1.5 dB/Min, 3 = 2.0
dB/Min, 4 = 2.5 dB/Min, 5 = 3.0 dB/Min, 6 = 3.5 dB/Min,
7 = 4.0 dB/Min, 8 = 4.5 dB/Min, 9 = 5.0 dB/Min, 10 =
5.5 dB/Min, 11 = 6.0 dB/min


Opcode: <262Eh>

Command AUPC Remote Baseband Loopback