Comtech EF Data DMD20 User Manual
Page 51
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol
Remote Operations
MN-DMDREMOTEOP Revision 9
1–41
<11> Tx Circuit ID
11 ASCII characters, null terminated
Opcode: <2622h>
Command Force Modulator Alarm Test
Command Data (1 Byte)
<1>
Forced Alarm Test
Bit 0 = Tx Major Alarm
Bits 1 – 7 = Spares
0 = Not Forced, 1 = Forced
Opcode: <2623h>
Command Modulator Data Invert
Command Data (1 Byte)
<1>
Data Invert
0 = None, 1 = Terrestrial, 2 = Baseband, 3 = Terrestrial
and Baseband
Opcode: <2625h>
Clear a Modulator’s Latched Alarm 1 (No Data)
Command Data (0 Bytes)
Opcode: <2629h>
Command AUPC Local Enable
Command Data (1 Byte)
<1>
AUPC Local Enable
0 = Off, 1 = EF AUPC, 2 = Radyne AUPC
Opcode: <262Ah>
Command AUPC Remote Enable
Command Data (1 Byte)
<1> AUPC
Remote
Enable
0 = Off, 1 = EF AUPC
Opcode: <262Bh>
Command AUPC Local CL Action
Command Data (1 Byte)
<1> AUPC
Local
CL
Action
0 = Hold, 1 = Nominal, 2 = Maximum
Opcode: <262Ch>
Command AUPC Remote CL Action
Command Data (1 Byte)
<1>
AUPC Remote CL
Action
0 = Hold, 1 = Nominal, 2 = Maximum
Opcode: <262Dh>
Command AUPC Tracking Rate
Command Data (1 Byte)
<1>
AUPC Tracking Rate
0 = 0.5 dB/Min, 1 = 1.0 dB/Min, 2 = 1.5 dB/Min, 3 = 2.0
dB/Min, 4 = 2.5 dB/Min, 5 = 3.0 dB/Min, 6 = 3.5 dB/Min,
7 = 4.0 dB/Min, 8 = 4.5 dB/Min, 9 = 5.0 dB/Min, 10 =
5.5 dB/Min, 11 = 6.0 dB/min
Opcode: <262Eh>
Command AUPC Remote Baseband Loopback