DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol
SNMP (MIB)
MN-DMDREMOTEOP Revision 9
2–50
baud1200(4),
baud2400(5),
baud4800(6),
baud9600(7),
baud19200(8),
baud38400(9),
baud57600(10),
baud115200(11)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects remote port Baud Rate."
::= { radDmd20CommonNVStatus 12 }
radDmd20CommonRemoteInterface OBJECT-TYPE
SYNTAX INTEGER {
rs232(1),
rs485(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects remote line interface type."
::= { radDmd20CommonNVStatus 13 }
radDmd20CommonEventClear OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Any write to this object clears the event buffer."
::= { radDmd20CommonNVStatus 14 }
radDmd20CommonLatchedAlarmsClear OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Any write to this object clears the latched alarms."
::= { radDmd20CommonNVStatus 15 }
radDmd20CommonMinorAlarmRelayUsage OBJECT-TYPE
SYNTAX INTEGER {
ibsPromptAndService(1),
minorAlarmsAndIbs(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the usage of two of the relay contacts on the baseband board.
When an IBS type Network spec is used this value is ignored and the
contacts are ibsPromptAndService only. In closed network configurations
the relays can be used for ibs prompt and service purposes or both ibs and
txMinor alarms and rxMinor alarms."
::= { radDmd20CommonNVStatus 16 }