Comtech EF Data DMD20 User Manual
Page 130
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol
SNMP (MIB)
MN-DMDREMOTEOP Revision 9
2–34
::= { radDmd20DemodNVStatus 44 }
radDmd20RxAlarms6Mask OBJECT-TYPE
SYNTAX BITS {
lnbCurrentFault(0),
lnbVoltageFault(1),
ethernetWanMajorAlarm(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Alarm mask:
0 = Mask, 1 = Allow"
::= { radDmd20DemodNVStatus 45 }
radDmd20RxCarrierReacqRange OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reacquisition range is -/+ selected value."
::= { radDmd20DemodNVStatus 46 }
radDmd20RxRsOfecRate OBJECT-TYPE
SYNTAX INTEGER (0..255255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This provides the ReedSolomon N and K Values, the integer
fieldValue = (N * 1000) + K
Example: a Dvb Code Rate of 188/204 has a field value of 204188 = (204 * 1000) + 188
A ReedSolomon N code is the codeword length or block length.
It is the sum of message and check symbols. N = K + R.
ReedSolomon K code is the message length or user data. It is
the number of user data symbols in one message block. Message
length is K = N - R."
::= { radDmd20DemodNVStatus 47 }
radDmd20RxIfecInterleaver OBJECT-TYPE
SYNTAX ControlType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Disables/Enables the TPC interleaver. Valid only for ldpc codes and turbo codes
TPC.495 and TPC.793"
::= { radDmd20DemodNVStatus 48 }
radDmd20RxCarrierSweepDelay OBJECT-TYPE
SYNTAX CarrierSweepDelayType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the carrier sweep delay in secs. There is an implied decimal point.
A value of 215 corresponds to a 21.5 sec sweep delay."