beautypg.com

Comtech EF Data DMD20 User Manual

Page 131

background image

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol

SNMP (MIB)

MN-DMDREMOTEOP Revision 9

2–35

::= { radDmd20DemodNVStatus 49 }

radDmd20RxEbnoAlarmThreshold OBJECT-TYPE
SYNTAX EbnoAlarmThresholdType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"EbNo alarm threshold. There is an implied decimal point."
::= { radDmd20DemodNVStatus 50 }

radDmd20RxBufferReset OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Any write to this object resets the buffer."
::= { radDmd20DemodNVStatus 51 }

radDmd20RxRestartTestPattern OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Any write to this object restarts the test pattern."
::= { radDmd20DemodNVStatus 52 }

radDmd20RxSccCtlRatio OBJECT-TYPE
SYNTAX INTEGER {
ratio1(1),
ratio2(2),
ratio3(3),
ratio4(4),
ratio5(5),
ratio6(6),
ratio7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects SCC format overhead ratio."
::= { radDmd20DemodNVStatus 53 }

radDmd20RxSccInbandRate OBJECT-TYPE
SYNTAX Unsigned32 (300..115200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the SCC format in-band overhead rate."
::= { radDmd20DemodNVStatus 54 }

radDmd20RxFastAcquisition OBJECT-TYPE
SYNTAX ControlType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Disables/enables the Rx fast acquisition capability"

This manual is related to the following products: