Comtech EF Data DMD20 User Manual
Page 113
DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol
SNMP (MIB)
MN-DMDREMOTEOP Revision 9
2–17
A ReedSolomon N code is the codeword length or block length.
It is the sum of message and check symbols. N = K + R.
ReedSolomon K code is the message length or user data. It is
the number of user data symbols in one message block. Message
length is K = N - R."
::= { radDmd20ModNVStatus 50 }
radDmd20TxIfecInterleaver OBJECT-TYPE
SYNTAX ControlType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Disables/Enables the IFEC interleaver. Valid only for ldpccodes and turbo codes
TPC.495 and TPC.793"
::= { radDmd20ModNVStatus 51 }
radDmd20TxEsEnhancedEnable OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
enhanced(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the async mode. Enhanced mode is only valid in Closed Net mode."
::= { radDmd20ModNVStatus 52 }
radDmd20TxEsSerialControlInterface OBJECT-TYPE
SYNTAX INTEGER {
rs232(1),
rs485(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the port type for enhanced async. This applies only if the async
mode is set to enhanced. This affects both transmit and receive interface
types."
::= { radDmd20ModNVStatus 53 }
radDmd20TxEsBaudRate OBJECT-TYPE
SYNTAX INTEGER {
baud150(1),
baud300(2),
baud600(3),
baud1200(4),
baud2400(5),
baud4800(6),
baud9600(7),
baud19200(8),
baud38400(9),
baud57600(10),
baud115200(11)
}
MAX-ACCESS read-write
STATUS current