Comtech EF Data DMD20 User Manual
Page 104

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol
SNMP (MIB)
MN-DMDREMOTEOP Revision 9
2–8
disable(1),
t1d4(2),
t1esf(3),
pcm30(4),
pcm30c(5),
pcm31(6),
pcm31c(7),
slc96(8),
t1d4s(9),
t1esfs(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the modulator drop mode. SLC-96 is not yet implemented
and is reserved for future use."
::= { radDmd20ModNVStatus 13 }
radDmd20TxDropMap OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the modulator drop map. Current mapping of satellite channels to
dropped terrestrial time slots. Valid drop channels are 1 through 31. If the
drop mode is either PCM-30 or PCM-30C, then the channel number 16 is reserved
for signaling."
::= { radDmd20ModNVStatus 14 }
radDmd20TxClockSource OBJECT-TYPE
SYNTAX INTEGER {
externalScte(1),
internalSct(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects Tx clock source. 1 selects the terrestrial clock (Scte),
2 selects the internal clock (Sct), and 3 the external Bnc clock."
::= { radDmd20ModNVStatus 15 }
radDmd20TxClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
inverted(2),
auto(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects clock polarity for Tx terrestrial clock relative to
Tx data."
::= { radDmd20ModNVStatus 16 }
radDmd20TxSctClockSource OBJECT-TYPE
SYNTAX INTEGER {