Comtech EF Data DMD20 User Manual
Page 59

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol
Remote Operations
MN-DMDREMOTEOP Revision 9
1–49
Status Bytes (88 Bytes)
<1>
Control Mode
0 = Front Panel, 1 = Terminal, 2 = Computer, Note:
DMD20 will always return 2 = Computer
<1>
Revision Number
Decimal point implied
<1>
Alarm 1
Bit 0 = Receive FPGA/Processor Fault, 1 = Fail
Bit 1 = Carrier Loss, 1 = Fail
Bit 2 = Multiframe Sync Loss, 1 = Fail
Bit 3 = Frame Sync Loss, 1 = Fail
Bit 4 = IBS BER Alarm, 1 = Fail
Bit 5 = Satellite AIS, 1 = Fail
Bit 6 = Rx Data Activity, 1 = Activity
Bit 7 = Rx AGC Level, 1 = Fail
<1>
Alarm 2
Bit 0 = Buffer Underflow, 1 = Underflow
Bit 1 = Buffer Overflow, 1 = Overflow
Bit 2 = Buffer Under 10%, 1 = Fail
Bit 3 = Buffer Over 90%, 1 = Fail
Bit 4 = RS Decoder Lock Fault, 1 = Fail
Bit 5 = RS De-Interleaver Fault, 1 = Fail
Bit 6 = RS Decoder Uncorrectable Word, 1 = Fail
Bit 7 = Demod Summary Fault, 1 = Fail
<1>
Alarm 3
Bit 0 = Rx L-Band Synthesizer Lock, 1 = Lock
Bit 1 = Insert DSP Config, 1 = Fail
Bit 2 = Buffer Clock PLL Lock Detect, 1 = Lock
Bit 3 = Viterbi Decoder Lock, 1 = Lock
Bit 4 = Sequential Decoder Lock, 1 = Lock
Bit 5 = Rx Test Pattern Lock, 1 = Lock
Bit 6 = External Reference PLL Lock, 1 = Lock
Bit 7 = Rx Carrier Level, 1 = Fail
<1>
Alarm 4
Bit 0 = Buffer Clock Activity Detect, 1 = Activity
Bit 1 = External BNC Activity Detect, 1 = Activity
Bit 2 = Rx Satellite Clock Activity Detect, 1 = Activity
Bit 3 = Insert Clock Activity Detect, 1 = Activity
Bit 4 = External Reference Activity Detect, 1 = Activity
Bit 5 = High Stability Reference PLL Activity, 1 =
Activity
Bit 6 = Reserved
Bit 7 = Low EbNo, 1 = Fail
<1>
Common Alarm 1
Bit 0 = -12V Alarm, 1 = Fail
Bit 1 = +12V Alarm, 1 = Fail
Bit 2 = +5V Alarm, 1 = Fail
Bits 3 – 5 = Reserved
Bit 6 = IF SYNTH Alarm, 1 = Fail
Bit 7 = Spare
<1>
Common Alarm 2
Bit 0 = TERR FPGA Config, 1 = Fail
Bit 1 = CODEC FPGA Config, 1 = Fail
Bit 2 = CODEC Device Config, 1 = Fail
Bit 3 = TRANSEC Power Test, 1 = Fail
Bit 4 = +1.5 V Rx Alarm, 1 = Fail
Bit 5 = +1.5 V TX Alarm, 1 = Fail
Bit 6 = +3.3 V Alarm, 1 = Fail
Bit 7 = +20 V Alarm, 1 = Fail