Comtech EF Data DMD20 User Manual
Page 133

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol
SNMP (MIB)
MN-DMDREMOTEOP Revision 9
2–37
radDmd20RxBufferClockSource2 OBJECT-TYPE
SYNTAX BufferClockSourceType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the second Rx Buffer Clock Source, e.g. the first fallback
Each radDmd20RxBufferClockSource should be unique
"
::= { radDmd20DemodNVStatus 61 }
radDmd20RxBufferClockSource3 OBJECT-TYPE
SYNTAX BufferClockSourceType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the third Rx Buffer Clock Source, e.g. the second fallback
Each radDmd20RxBufferClockSource should be unique
"
::= { radDmd20DemodNVStatus 62 }
radDmd20RxBufferClockSource4 OBJECT-TYPE
SYNTAX BufferClockSourceType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the fourth Rx Buffer Clock Source, e.g. the third fallback
Each radDmd20RxBufferClockSource should be unique
"
::= { radDmd20DemodNVStatus 63 }
radDmd20RxBufferClockSource5 OBJECT-TYPE
SYNTAX BufferClockSourceType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the fifth Rx Buffer Clock Source, e.g. the fourth fallback
Each radDmd20RxBufferClockSource should be unique
"
::= { radDmd20DemodNVStatus 64 }
radDmd20RxAsyncInbandRate OBJECT-TYPE
SYNTAX INTEGER {
inband150(1),
inband300(2),
inband600(3),
inband1200(4),
inband2400(5),
inband4800(6),
inband9600(7),
inband19200(8),
inband38400(9),
inband57600(10),
inband115200(11)
}