beautypg.com

Comtech EF Data DMD20 User Manual

Page 48

background image

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol

Remote Operations

MN-DMDREMOTEOP Revision 9

1–38

Opcode: <2608h>

Command a Modulator’s Differential Encoder

Command Data (1 Byte)

<1>

Differential Encoder

0 = Disabled, 1 = Enabled


Opcode: <2609h>

Command a Modulator’s Carrier Control

Command Data (1 Byte)

<1>

Carrier Control

0 = Off, 1 = On, 2 = Auto, 3 = VSAT, 4 = RTS (Refer To
Appendix E)


Opcode: <260Ah>

Command a Modulator’s Carrier Selection

Command Data (1 Byte)

<1>

Carrier Selection

0 = Normal, 1 = CW, 2 = Dual, 3 = Offset, 4 = Pos Fir, 5
= Neg Fir


Opcode: <260Bh>

Command a Modulator’s Clock Control

Command Data (1 Byte)

<1>

Clock Control

0 = SCTE, 1 = SCT


Opcode: <260Ch>

Command a Modulator’s Clock Polarity

Command Data (1 Byte)

<1>

Clock Polarity

0 = Normal, 1 = Inverted, 2 = Auto


Opcode: <260Dh>

Command a Modulator’s SCT Source

Command Data (1 Byte)

<1>

SCT Source

0 = Internal, 1 = SCR


Opcode: <260Eh>

Command a Modulator’s Drop Mode

Command Data (1 Byte)

<1>

Drop Mode

0 = Disabled, 1 = T1-D4, 2 = T1-ESF, 3 = PCM-30, 4 =
PCM-30C, 5 = PCM-31, 6 = PCM-31C, 7 = SLC-96, 8 =
T1 D4 S, 9 = T1 ESF S


Opcode: <260Fh>

Command a Modulator’s Output Level

Command Data (2 Bytes)

<2>

Transmit Power Level For DMD20 Signed value, 0 to -250 (0.0 to -25.0 dBm)

(two’s compliment)
For OM20 Signed value, -200 to -450 (-20.0 to -45.0
dBm)
For DMD2050E Signed value. 0 to -450 (0.0 to -45.0
dBM)


Opcode: <2610h>

Command a Modulator’s Reed-Solomon

Command Data (1 Byte)