Comtech EF Data DMD20 User Manual
Page 115

DMD20/DMD50/DMD2050/DMD2050E/DMD1050/OM20 Remote Protocol
SNMP (MIB)
MN-DMDREMOTEOP Revision 9
2–19
}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Selects Sct clock polarity."
::= { radDmd20ModNVStatus 59 }
radDmd20TxCompensation OBJECT-TYPE
SYNTAX RadTransmitCompensation
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets upto a 1 dBm Tx Power compensation for local cabling and connections"
::= { radDmd20ModNVStatus 60 }
radDmd20TxForceAlarmTest OBJECT-TYPE
SYNTAX BITS {
forceMajorAlarmTest(0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tx forced alarms:
0=Do not force, 1=Force alarm"
::= { radDmd20ModNVStatus 61 }
radDmd20TxAsyncInbandRate OBJECT-TYPE
SYNTAX INTEGER {
inband150(1),
inband300(2),
inband600(3),
inband1200(4),
inband2400(5),
inband4800(6),
inband9600(7),
inband19200(8),
inband38400(9),
inband57600(10),
inband115200(11)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects Efficient D&I format Inband Rate"
::= { radDmd20ModNVStatus 62 }
radDmd20TxEthQosType OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
portBased(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects Quality of Service Type."