Basler Electric BE1-700 User Manual
Instruction manual, Digital protective relay be1-700
This manual is related to the following products:
Table of contents
Document Outline
- BE1-700
- Introduction
- Revision History
- Contents
- 1-General Information
- DESCRIPTION
- FEATURES
- MODEL AND STYLE NUMBER DESCRIPTION
- OPERATIONAL SPECIFICATIONS
- Metered Current Values and Accuracy (BE1-700C)
- Metered Voltage Values and Accuracy (BE1-700V)
- Metered Frequency Values and Accuracy (BE1-700V)
- Calculated Values and Accuracy
- 24 Overexcitation Protection (BE1-700V)
- 25 Sync-Check Protection (BE1-700V, Optional)
- 27P Phase Undervoltage Protection (BE1-700V)
- 27X Auxiliary Undervoltage Protection (BE1-700V)
- 47 Negative-Sequence Overvoltage Protection (BE1-700)
- 50T Instantaneous Overcurrent Protection (BE1-700C)
- 50BF Breaker Failure Protection (BE1-700C)
- 51 Time Overcurrent Protection (BE1-700C)
- 59P Phase Overvoltage Protection (BE1-700V)
- 59X Auxiliary Overvoltage Protection (BE1-700V)
- 60FL Fuse Loss (BE1-700V)
- 62 Logic Timers
- 79 Recloser Protection
- 81 Over/Under Frequency Protection (BE1-700V)
- Automatic Setting Group Characteristics
- BESTlogic™
- GENERAL SPECIFICATIONS
- AC Current Inputs (BE1-700C)
- Phase AC Voltage Inputs (BE1-700V)
- Auxiliary AC Voltage Inputs
- Analog to Digital Converter
- Power Supply
- Output Contacts
- Contact-Sensing Inputs
- IRIG
- Real-Time Clock
- Communication Ports
- Display
- Isolation
- Surge Withstand Capability
- Radio Frequency Interference (RFI)
- Electrostatic Discharge (ESD)
- Shock
- Vibration
- Environment
- CE Compliance
- UL Recognition for US and Canada
- GOST-R Certification
- Physical
- 2-Quick Start
- 3-Input and Output Functions
- 4-Protection and Control
- 5-Metering
- 6-Reporting and Alarm Functions
- 7-BESTlogic Programmable Logic
- 8-Application
- INTRODUCTION
- EXPLANATION OF TERMS
- OVERVIEW OF PREPROGRAMMED LOGIC SCHEMES
- EMBEDDED LOGIC SCHEMES FOR BE1-700C
- EMBEDDED LOGIC SCHEMES FOR BE1-700V
- DETAILS OF PREPROGRAMMED LOGIC SCHEMES
- 700C-5051-A-BE (BASIC OVERCURRENT) LOGIC SCHEME (BE1-700C)
- 700COC79ABE (OVERCURRENT WITH RECLOSING) LOGIC SCHEME (BE1-700C)
- 700V-OUVF-A-BE (OVER/UNDER V & F PROTECTION) LOGIC SCHEME (BE1-700V)
- 700V-VF79-A-BE (VOLTAGE PROTECTION WITH RECLOSING) LOGIC SCHEME (BE1-700V)
- MISCELLANEOUS LOGIC EXPRESSIONS
- APPLICATION TIPS
- Output Contact Latch Using the TRSTKEY Logic Variable
- Alarm Latch and Pseudo Target Using the ARSTKEY Logic Variable
- Underfrequency Load Shedding with Restoration Permissive (BE1-700V)
- Logic Equations and Settings, Underfrequency Load Shedding
- Close Circuit Monitor
- High-Speed Reclose
- Block Load Tap Changer
- Setting Group Selection
- Output Contact Seal-In
- 9-Security
- 10-Human-Machine Interface
- 11-ASCII Command Interface
- 12-Installation
- 13-Testing and Maintenance
- GENERAL
- TESTING PHILOSOPHIES
- TESTING AND TROUBLESHOOTING AIDS
- ACCEPTANCE TESTING
- Test Equipment
- Power Up
- Communications
- Style Number and Serial Number Verification
- IRIG Verification (if used)
- Contact Sensing Inputs
- Control Outputs
- Current Circuit Verification (BE1-700C)
- Three-Phase Voltage Circuit Verification (BE1-700V)
- Auxiliary Voltage Input Verification - VX and VX 3rd (Fundamental and Third Harmonic) (BE1-700V)
- Line and Bus Angle, Frequency, and Slip Verification
- COMMISSIONING TESTING
- PERIODIC TESTING
- CARE AND HANDLING
- STORAGE
- UPDATING FIRMWARE AND SOFTWARE
- FUNCTIONAL TESTING
- Instantaneous Overcurrent (50T) (BE1-700C)
- Time Overcurrent (51) (BE1-700C)
- Volts per Hertz Overexcitation (24) (BE1-700V)
- Phase and Auxiliary Undervoltage/Overvoltage (27/59) (BE1-700V)
- Negative-Sequence Voltage (47) (BE1-700V)
- Over/Underfrequency (81) (BE1-700V)
- Synchronism Check (25) (Optional)
- Breaker Failure (BF) (BE1-700C)
- Virtual Switches (43)
- Virtual Breaker Control Switch (101)
- Logic Timer (62)
- Automatic Setting Group Change
- 14-BESTCOMS Software
- DESCRIPTION
- INTRODUCTION
- INSTALLATION
- UPDATING BESTCOMS™ SOFTWARE
- STARTING BESTCOMS™
- CONFIGURING THE PC
- SETTING THE RELAY
- Select Logic Scheme for Display
- Settings Display and Selection
- General Operation Screen
- Setting Group Selection
- Overcurrent Protection (BE1-700C)
- Voltage Protection (BE1-700V)
- Reclosing (Optional)
- Breaker Failure (BE1-700C)
- Logic Timers
- Reporting and Alarms
- Inputs and Outputs
- Virtual Switches
- BESTNet Settings
- BESTlogic
- COPYING SETTINGS FROM GROUP TO GROUP
- DOWNLOADING OSCILLOGRAPHY FILES
- METERING
- FILE MANAGEMENT
- SETTINGS COMPARE
- BESTprint™
- 15-BESTnet Communication
- A-Time Overcurrent Characteristic Curves
- B-Command Cross-Reference
- C-Terminal Communication
- D-Overexcitation Inverse Time Curves