Setting method – KEYENCE LS-7000 User Manual
Page 97

4-45
Chapter 4 Function Settings
4
The following table shows the relationship of scaling values along with their output
ranges and resolutions.
Scaling value [
μm/V]
Output range
Resolution (
❈)
1
±10μm
0.01
μm
2
±20μm
0.01
μm
5
±50μm
0.02
μm
10
±100μm
0.04
μm
20
±200μm
0.08
μm
50
±500μm
0.2
μm
100
±1mm
0.4
μm
200
±2mm
0.8
μm
500
±5mm
2
μm
1000
±10mm
4
μm
2000
±20mm
8
μm
5000
±50mm
20
μm
10000
±100mm
40
μm
❈If the minimum display unit selected is larger than the resolution selected, the mini-
mum display unit will be used as applicable resolution.
■ Setting Method
1
Press the
ENT
key when the output
setting is displayed.
2
Press the
FUNC
key four times.
Measured value
0V
+10.5V
+10V
Voltage
–10V
0
30
–10.5V
(Positive value
over range)
(Negative value
below range)
+10V :30mm
–10V : 0mm
HI
GO
LO
3
Press the
or
key and set the scaling value.
4
Press the
ENT
key.
The input item is entered and the output setting display appears again.
● Tolerance Mode with Threshold
Set the measurement values to be output at
10 V and –10 V respectively so that the
scaling value will be decided. The voltage
can be changed while the result waiting
status is “---.-----.” (See Page 4-47)