Difference check, Setting method, Chapter 4 function settings – KEYENCE LS-7000 User Manual
Page 68: Select the area to be set and press the, Press the, Key three times, Press the or key and set the averaging number, Press the or key and set the difference value
4-16
Chapter 4 Function Settings
4
Difference Check
If there is a radical change between measured values, the change will be detected and
output.
Setting Range
• Difference average: 1 to 16 times
• Difference value: 1 to 9999
μm
Note:
The results of difference checks will be output externally, provided that DIFF
function output settings are made properly in advance. Refer to Function
Output Selection on page 4-19 for details.
The result output of a difference check is a 26.6-ms-long single output signal,
which is not displayed on the control panel.
■ Setting Method
1
Select the area to be set and press
the
ENT
key.
2
Press the
FUNC
key three times.
3
Press the
or
key and set the averaging number.
The setting
part flashes.
Press these
keys to set
the value.
Averaging times
PROG No.
AREA
DISP
ESC
PROG
FUNC
ENT
H
ZE
FOCUS
2
1
A R E A
POSITION
G
L
4
Press the
ENT
key.
The input value is entered and the difference value display flashes.
5
Press the
or
key and set the difference value.
PROG No.
AREA
DISP
ESC
PROG
FUNC
ENT
H
ZE
FOCUS
2
G
L
The setting
part flashes.
Difference
value
Press these keys
to set the value.
HI
GO
LO