Application Example of Measuring modes
Select the measurement mode according to the type of target and measuring condition.
The following applications are typical examples of measurement in a variety of Measur-
ing modes.
Application
Applicable RUN mode
Normal
Continuous measurement of 
wire, tube, or fiber
Peak Hold
Auto Peak Hold
Measurement of maximum 
value within specified period
Bottom Hold
Auto Bottom Hold
Measurement of minimum 
value within specified period
Peak-to-peak Hold
Auto Peak-to-peak Hold
Measurement of maximum-to-
minimum value within specified 
period
Average Hold
Measurement of average 
values within specified period
Peak Hold
Auto Peak Hold
Measurement of maximum 
value per rotation
Bottom Hold
Auto Bottom Hold
Measurement of minimum 
value per rotation
Peak-to-peak Hold
Auto Peak-to-peak Hold
Measurement of maximum-to-
minimum fluctuation or 
eccentricity per rotation
Average Hold
Measurement of average value 
per rotation
Sample Hold 1
Sample Hold 2
Self-timing Hold
Single workpiece 