1 removing the drive bay assembly, Removing the drive bay assembly – Kontron TIGH2U Carrier Grade Server User Manual
Page 93

Kontron Carrier Grade Server TIGH2U
December 2009
Product Guide, rev.1.2
93
Server Component Replacements—TIGH2U Server
5.5
Replacing the Removable Drive Bay Assembly and the SAS
Backplane Board
The drive bay assembly can be removed and placed in another server or swapped out for another
assembly using the same HDDs. The drive bay assembly must be removed to replace the SAS
backplane board or power distribution board (PDB) module.
Caution:
Before replacing any of the boards or components in the TIGH2U Server, you must first
take the server out of service, turn off all peripheral devices connected to the system,
turn off the system by pressing the power button, and unplug the power cord(s) from
the system or wall outlet.
5.5.1
Removing the Drive Bay Assembly
1. Remove the chassis cover. For instructions, see
Section 3.2.3, “Removing the Chassis Cover” on
2. Remove the front bezel. For instructions, see
Section 3.2.1, “Removing the Front Bezel” on
1. Disconnect the cables that are attached to the SAS backplane board at the rear of the drive bay
assembly:
— flex cable
— power cable from the SFP board
— IDE cable from the server board
2. Loosen the screw on the PCI fan assembly.
3. Lift the PCI fan assembly from position. It is not necessary to disconnect the fan cables.
4. Remove the three screws from the left side of the chassis and the two screws on the right side of
the drive bay front panel. (
, “A”, “B”)
5. Pull the drive bay assembly from the chassis. (“C”)
Figure 73.
Removing the Drive Bay Assembly
A
B
C
TS000313