10 power supply, 11 system cooling, 10 power supply 2.11 system cooling – Kontron TIGH2U Carrier Grade Server User Manual
Page 22

TIGH2U Server—Features
Kontron Carrier Grade Server TIGH2U
Product Guide, rev.1.2
December 2009
22
2.10
Power Supply
The power subsystem has a power distribution board (PDB) and up to two hot-swap power supply
modules capable of operating in redundant mode. A power supply filler panel for the empty power
supply site is supplied for systems without redundancy.
The power supply is rated for 600 W output capability in full AC (or DC) input voltage range.
2.11
System Cooling
There are three cooling areas (domains) in the TIGH2U Server system:
• Domain 1 - CPU 1 and memory; see area outlined in blue in
• Domain 2 - CPU 2, chipset, and any low-profile PCIe add-in cards; see area outlined in green in
• Domain 3 - any full length PCI-X or PCIe add-in cards; see area outlined in red in
Letter A in the following figure calls out the PCI fans. Letter B calls out the CPU fans.
Figure 8.
System Cooling Areas
A
B
TS000419