TIGH2U Server—Server Component Replacements
Kontron Carrier Grade Server TIGH2U
Product Guide, rev.1.2
December 2009
90
5. Remove the TAM board. For instructions, see
Section 5.3.1, “Removing the TAM Board” on
.
6. Remove the PCI fan assembly. For instructions, see
Section 5.2.4, “Removing the PCI Fan
7. Remove the CPU fan assembly. For instructions, see
Section 5.2.1, “Removing the CPU Fan
8. Disconnect all of the cables connected to the SFP board:
— SAS backplane power cable
— All four fan power cables
— Two power input cables from the power distribution board
— Flex cable
— Intel
®
RAID Smart Battery cable, if the smart battery is installed
— Front serial port cable
Use
Section 35, “System Cable Routing” on page 53
as a reference for the connectors.
9. Open the bridge board connector latches. (
, “A”)
10. Lift the bridge board from the chassis (“B” and “C”)
Figure 70.
Removing the Bridge Board
TS000435
B
C
A
11. Remove the SFP board screw (
, “A”).
12. Remove the threaded TAM board standoff. (“B”)