• Click the D.C. Functions button then click Delete list. If the selected

list(s) have data that has not been unloaded, you will lose both the
selected lists and associated data.

Why won’t Emonitor load a list to the Enpac Ex?

First, check the communication between Emonitor and the Enpac Ex. Note
that the baud rate setting in the data collector must match the baud rate setting
in Emonitor.

If the communication link between them is correct, it may be that the list

is

already loaded in the Enpac Ex. You must either delete the list or initialize the
memory before you can reload a list already in the Enpac Ex.

Why does Emonitor rebuild the Quickload files?

Emonitor rebuilds a Quickload file before loading it to the data collector when
any one of the following occur.

• The list is not stored with the Use quickload file option selected.
• The measurement definitions in the list change.
• The inspection codes in the list change.
• The locations in the list change.
• The hierarchy level of items in the Hierarchy Tree that affect

measurement definitions in the list change.

• The collection specification of a measurement definition in the list

changes.

• The Override collect on alarm settings (in the Load Option dialog

box) is selected.

• The list has been saved since last loaded.

How do I tell when loading or unloading is done?

Emonitor and the Enpac Ex establish communication as soon as the following
are both true.

• The Enpac Ex is correctly connected to the computer.
• You select Tools > Load/Unload in Emonitor.