106 Enpac Ex Parameters

Date/Time

Sets the data and time in the Enpac Ex. See Setting
the Date, Time, and Date Format on page 22
for
instructions.

Touchscreen

Controls the Windows CE touchscreen calibration
routine.

select cmd - Exit this field without selecting an

option.

Calibrate - Immediately starts the Windows CE

touchscreen calibration routine. Once the
calibration routine is finished, the Touchscreen
option will be set to "select cmd."

Options: select cmd (default)

Calibrate

Memory

Configures the memory.

select cmd - Exit this field without selecting an

option.

Delete all routes - Deletes all routes and data

from memory.

Initialize - Formats the memory. Deletes all files

from memory including any route files and
directories.

Options: select cmd (default)

Delete all routes
Initialize

Purge Cache

Mechanism to speed up the purging point data of
large database. Creates cached empty database file
for faster purging.

Options: On (default)

Off

Note: To maximize storage space, set
Purge Cache to "Off."

Envelope

The type of envelope to use for high frequency and
rolling element bearing analysis.

Options: gSE (default)

ESP

Important: Determines which
pre-defined measurement you can use
to collect off route data.

Set Envelope to "ESP" to collect an
off route ESP point. Set Envelope to
"gSE" to collect an off route gSE point.
See Collecting Off Route Data using a
Pre-Defined Measurement on
page 90.