Adjusting Voltage and Current Regulation Parameters

9-7

Processing Bus Data and Making Necessary Error Corrections in the PI
Regulator

The PI (proportional-integral) regulator is responsible for making the
necessary corrections to reduce the error signal (P142). Refer to
Figure 9.6 for the PI regulator firmware diagram. In addition to
having proportional and integral correction capabilities, the PI
regulator also has the added feature of an error limiter.

The error limiter provides additional correction whenever the error
signal exceeds the maximum error signal allowable (P115). The error
limiter is only functional when the error limiter has been turned on
and the RGU is regenerating.

Once the corrected I

q

command has been calculated (P121), the

linearizer can be used to keep the I

q

command fairly constant when

the installation is subject to fluctuations in the AC line and DC bus
voltages.

Figure 9.6
Firmware Diagram for Processing Bus Data and Making Necessary Error
Corrections in the PI Regulator

Bus Fdbk'

Line Voltage'

Linearizer

Error Limiter

142

115

116

117

118

kp/8

Prop. Gain

1

35

ki/8

S

Intg. Gain

119

121

3

35

84

120

+

+

+

Error

Signal

Iq Necessary for
Error Correction

X

X

Y

X

X

X

*

Indirect, parameter X

Source; parameter X

Sink; parameter X

Parameter X, bit Y

Battery-backed, parameter X

SYMBOL KEY

Parameter Number

Parameter Name

35 bit 1

Host Mode - Error Limiter

35 bit 3

Host Mode - Linearizer

84

Voltage Regulator Output

115

Voltage Loop PI Error Limit

116

Voltage Loop Error Limit Step

117

Voltage Loop Error Gain Limit

118

Voltage Loop Proportional Gain

119

Voltage Loop Integral Gain

120

Voltage Loop Inegrator Output

121

Voltage Loop PI Output

140

Bus Prefiltered Feedback

Parameter Number

Parameter Name