Firmware Compatibility

Table 2 shows the firmware versions that may be installed in a
particular unit. Note that Series B, M and N-code units can only
operate with firmware version 3.01 or 3.02, and Series A, M and
N-code RGUs cannot operate with firmware version 3.01 or 3.02.

Table 2: Firmware Compatibility

Version

Series A

Series B

J

K

L

M

N

M

N

1.02

Y

Y

Y

Y

Y

N

N

2.01

Y

Y

Y

Y

Y

N

N

2.02

Y

Y

Y

Y

Y

N

N

2.03

Y

Y

Y

Y

Y

N

N

3.01

Y

Y

Y

N

N

Y

Y

3.02

Y

Y

Y

N

N

Y

Y

AC INPUT

DC OUTPUT

CAT

2364FA-MNB

SER B

Refer to user manual for
installation instructions

CONSTANT TORQUE

541

460

678

3 50/60

524

683

749

-

DC

VOLTS

A

Hz

KVA

PH

Current Code

Series

Data nameplate located on power structure

1 9 2 3 9 0 U 1 2

1 9 9 9 V3 .0 1

©

Main Control Board

Firmware Label