Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual
Page 346

Publication 1756-UM522B-EN-P - February 2003
C-94 1756-DMF30 Specific Information
2204
Out Curr Rating
Enter the Power Modules 100% output DC Amp rating.
Units:
Default:
Min:
Max:
Type:
File:
Group:
Amps
1
1
32767
Non-Linkable, Read-Write, 16-Bit Integer
DPS/PMI
Drive Config
2205
Curr Xfmr Ratio
Defines the input to output ratio of the current transformer in
the Power Module. This value can be found on the Power
Module's nameplate.
Default:
Min:
Max:
Type:
File:
Group:
1
1
32767
Non-Linkable, Read-Write, 16-Bit Integer
DPS/PMI
Drive Config
2206
Field AC ln Volt
Enter the nominal voltage at the Field Power Module input. If
an isolation transformer is used, enter the secondary voltage.
Units:
Default:
Min:
Max:
Type:
File:
Group:
Volt
1
1
32767
Non-Linkable, Read-Write, 16-Bit Integer
DPS/PMI
Drive Config
2207
Fld OutCurrRatng
Enter the Field Power Module's DC Amps output rating. This
value can be found on the Power Module's nameplate.
Units:
Default:
Min:
Max:
Type:
File:
Group:
Amps
15
1
327.67
Non-Linkable, Read-Write, 16-Bit Integer
DPS/PMI
Drive Config
2208
Anlg Tach Volts
Enter the tachometer voltage that will be present when the
motor is turning at the speed specified in parameter
2181[Overspd Trip Pt].
Units:
Default:
Min:
Max:
Type:
File:
Group:
Volt
5
5
327.67
Non-Linkable, Read-Write, 16-Bit Integer
DPS/PMI
Drive Config
No.
Name
Description
Values