Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual
Page 319
![background image](/manuals/579192/319/background.png)
Publication 1756-UM522B-EN-P - February 2003
1756-DMF30 Specific Information C-67
1172
SL Buf Real Tx05
Provides floating point (real) data for Direct Transmit word 5, if
the data type for word 5 (indicated in parameter 1160 [Tx Buf
Data Type]) is real.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
SynchLink
Buffered DataOut
1173
SL Buf Int Tx06
Provides integer data for Direct Transmit word 6, if the data
type for word 6 (indicated in parameter 1160 [Tx Buf Data
Type]) is integer.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-Bit Integer
SynchLink
Buffered DataOut
1174
SL Buf Real Tx06
Provides floating point (real) data for Direct Transmit word 6, if
the data type for word 6 (indicated in parameter 1160 [Tx Buf
Data Type]) is real.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
SynchLink
Buffered DataOut
1175
SL Buf Int Tx07
Provides integer data for Direct Transmit word 7, if the data
type for word 7 (indicated in parameter 1160 [Tx Buf Data
Type]) is integer.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-Bit Integer
SynchLink
Buffered DataOut
1176
SL Buf Real Tx07
Provides floating point (real) data for Direct Transmit word 7, if
the data type for word 7 (indicated in parameter 1160 [Tx Buf
Data Type]) is real.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
SynchLink
Buffered DataOut
1177
SL Buf Int Tx08
Provides integer data for Direct Transmit word 8, if the data
type for word 8 (indicated in parameter 1160 [Tx Buf Data
Type]) is integer.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-Bit Integer
SynchLink
Buffered DataOut
1178
SL Buf Real Tx08
Provides floating point (real) data for Direct Transmit word 8, if
the data type for word 8 (indicated in parameter 1160 [Tx Buf
Data Type]) is real.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
SynchLink
Buffered DataOut
1179
SL Buf Int Tx09
Provides integer data for Direct Transmit word 9, if the data
type for word 9 (indicated in parameter 1160 [Tx Buf Data
Type]) is integer.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-Bit Integer
SynchLink
Buffered DataOut
No.
Name
Description
Values