Parameter 1229 [sl error status – Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual
Page 243
Publication 1756-UM522B-EN-P - February 2003
1756-DMD30 Specific Information B-163
Parameter 1229 [SL Error Status]
This parameter indicates the occurance of SynchLink errors.
29
Lgx Timeout
Communications with the Logix Controller has timed out.
30
Lgx Closed
The Logix Controller has closed a connection to the Drive
Module.
31
Lgx LinkChng
A required parameter link relating to a communications
connection has been modified.
Bit
Fault Name
Fault Description
0
Sync Loss
SynchLink communication has failed, after it had been
established.
1
Rx Loss
The receive port is not receiving data, and the receive port
configuration is set to receive data.
2
Many BOF Err
The number of BOF (Beginning Of Frame) errors accumulated
in parameter 1232 [SL BOF Err Accum] exceeds the value in
parameter 1235 [SL BOF Err Limit].
3
Many CRC Err
The number of CRC (Cycling Ring Checksum) errors
accumulated in parameter 1230 [SL CRC Err Accum] exceeds
the value in parameter 1234 [SL CRC Err Limit].
4
Pckg Msg Err
The received package sequence number has not matched for
1.0 S.
5
CommForm Err
The format of received data does not match the
configuration of the receive port.
6
Sys Rev Err
The system revision in received data does not match the
value of parameter 1001 [SynchLink Rev].
7
Mult TKeeper
More than one node on the SynchLink system is configured
as a Time Keeper.
Bit
Fault Name
Fault Description