Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual
Page 206
Publication 1756-UM522B-EN-P - February 2003
B-126 1756-DMD30 Specific Information
1204
SL Buf Real Tx21
Provides floating point (real) data for Direct Transmit word 21,
if the data type for word 21 (indicated in parameter 1160 [Tx
Buf Data Type]) is real.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
SynchLink
Buffered DataOut
1205
SL Buf Int Tx22
Provides integer data for Direct Transmit word 22, if the data
type for word 22 (indicated in parameter 1160 [Tx Buf Data
Type]) is integer.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-bit Integer
SynchLink
Buffered DataOut
1206
SL Buf Real Tx22
Provides floating point (real) data for Direct Transmit word 22,
if the data type for word 22 (indicated in parameter 1160 [Tx
Buf Data Type]) is real.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
SynchLink
Buffered DataOut
1207
SL Buf Int Tx23
Provides integer data for Direct Transmit word 23, if the data
type for word 23 (indicated in parameter 1160 [Tx Buf Data
Type]) is integer.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-bit Integer
SynchLink
Buffered DataOut
1208
SL Buf Real Tx23
Provides floating point (real) data for Direct Transmit word 23,
if the data type for word 23 (indicated in parameter 1160 [Tx
Buf Data Type]) is real.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
SynchLink
Buffered DataOut
1209
SL Buf Int Tx24
Provides integer data for Direct Transmit word 24, if the data
type for word 24 (indicated in parameter 1160 [Tx Buf Data
Type]) is integer.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-bit Integer
SynchLink
Buffered DataOut
1210
SL Buf Real Tx24
Provides floating point (real) data for Direct Transmit word 24,
if the data type for word 24 (indicated in parameter 1160 [Tx
Buf Data Type]) is real.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
SynchLink
Buffered DataOut
1211
SL Buf Int Tx25
Provides integer data for Direct Transmit word 25, if the data
type for word 25 (indicated in parameter 1160 [Tx Buf Data
Type]) is integer.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-bit Integer
SynchLink
Buffered DataOut
No.
Name
Description
Values