Publication 1756-UM522B-EN-P - February 2003

1756-DMD30 Specific Information B-111

1075

SL Buf Int Rx01
Displays the integer value of the Buffered Received Data for
word 1. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1076 [SL Buf Real Rx01].

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
SynchLink
Buffered Data In

1076

SL Buf Real Rx01
Displays the floating point (real) value of the Buffered
Received Data for word 1. Data transmitted from one node to
another must be the same data type. This parameter is paired
with paramter 1075 [SL Buf Int Rx01].

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
SynchLink
Buffered Data In

1077

SL Buf Int Rx02
Displays the integer value of the Buffered Received Data for
word 2. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1078 [SL Buf Real Rx02].

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
SynchLink
Buffered Data In

1078

SL Buf Real Rx02
Displays the floating point (real) value of the Buffered
Received Data for word 2. Data transmitted from one node to
another must be the same data type. This parameter is paired
with paramter 1079 [SL Buf Int Rx02].

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
SynchLink
Buffered Data In

1079

SL Buf Int Rx03
Displays the integer value of the Buffered Received Data for
word 3. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1080 [SL Buf Real Rx03].

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
SynchLink
Buffered Data In

1080

SL Buf Real Rx03
Displays the floating point (real) value of the Buffered
Received Data for word 3. Data transmitted from one node to
another must be the same data type. This parameter is paired
with paramter 1079 [SL Buf Int Rx03].

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
SynchLink
Buffered Data In

1081

SL Buf Int Rx04
Displays the integer value of the Buffered Received Data for
word 4. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1082 [SL Buf Real Rx04].

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
SynchLink
Buffered Data In

1082

SL Buf Real Rx04
Displays the floating point (real) value of the Buffered
Received Data for word 4. Data transmitted from one node to
another must be the same data type. This parameter is paired
with paramter 1081 [SL Buf Int Rx04].

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
SynchLink
Buffered Data In

No.

Name
Description

Values