Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual
Page 108
Publication 1756-UM522B-EN-P - February 2003
B-28 1756-DMD30 Specific Information
43
S Curve Spd Ref
Displays the speed command after the s-curve block, modified
by parameter 34 [S Curve Time]. A value of 1.0 represents
base speed of the motor.
Units:
Default:
Min:
Max:
Type:
File:
Group:
RPM
0
-14000
14000
Non-Linkable, Read Only, Floating Point
Speed Control
Reference
44
Filtered Spd Ref
Displays the speed reference value output from the reference
Lead/Lag filter. A value of 1.0 represents base speed of the
motor.
Units:
Default:
Min:
Max:
Type:
File:
Group:
RPM
0
-14000
14000
Non-Linkable, Read Only, Floating Point
Speed Control
Reference
45
Delayed Spd Ref
One sample period delayed output of parameter 43 [S Curve
Spd Ref]. Used in some applications to phase synchronize the
speed reference value through SynchLink. This parameter
would be utilized in place of [S Curve Spd Ref] in the master
drive. [S Curve Spd Ref] would then be transmitted to the
slave drives over SynchLink. A value of 1.0 represents base
speed of the motor.
Units:
Default:
Min:
Max:
Type:
File:
Group:
RPM
0
-14000
14000
Non-Linkable, Read Only, Floating Point
Speed Control
Reference
46
Scaled Spd Ref
Displays the speed command after scaling (the product of
parameter 44 [Filtered Spd Ref] and parameter 38 [Speed Ref
Scale]. A value of 1.0 represents base speed of the motor.
Units:
Default:
Min:
Max:
Type:
File:
Group:
RPM
0
-14000
14000
Non-Linkable, Read Only, Floating Point
Speed Control
Reference
47
Spd Trim1 SpdRef
The final speed command that will be utilized by the Speed
Regulator. It is the sum of the parameter 46 [Scaled Spd Ref]
and parameter 21 [Speed Trim1]. A value of 1.0 represents
base speed of the motor.
Units:
Default:
Min:
Max:
Type:
File:
Group:
RPM
0
-14000
14000
Non-Linkable, Read Only, Floating Point
Speed Control
Reference, Regulator
No.
Name
Description
Values