Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual
Page 231

Publication 1756-UM522B-EN-P - February 2003
1756-DMD30 Specific Information B-151
2204
Out Curr Rating
Enter the Power Module rated DC output Amps, from the
Power Module’s nameplate.
Units:
Default:
Min:
Max:
Type:
File:
Group:
Amps
1
1
32767
Non-Linkable, Read-Write, 16-bit Integer
DPS/PMI
Drive Config
2205
Curr Xfmr Ratio
Defines the input to output ratio of the current transformer in
the Armature Power Module.
Default:
Min:
Max:
Type:
File:
Group:
1
1
32767
Non-Linkable, Read-Write, 16-bit Integer
DPS/PMI
Drive Config
2206
Field AC In Volt
Enter the nominal voltage at the Field Power Module input. If
an isolation transformer is used, enter the secondary voltage.
Units:
Default:
Min:
Max:
Type:
File:
Group:
Volt
1
1
32767
Non-Linkable, Read-Write, 16-bit Integer
DPS/PMI
Drive Config
2207
Fld OutCurrRatng
Enter the Field Power Module's DC Amps output rating. This
value can be found on the Power Module's nameplate.
Units:
Default:
Min:
Max:
Type:
File:
Group:
Amps
15
1
327.67
Non-Linkable, Read-Write, 16-bit Integer
Monitor
Drive Data
2208
Anlg Tach Volts
Enter the tachometer voltage that will be present when the
motor is turning at the speed specified in parameter
2181[Overspd Trip Pt].
Units:
Default:
Min:
Max:
Type:
File:
Group:
Volt
5
5
327.67
Non-Linkable, Read-Write, 16-bit Integer
DPS/PMI
Drive Config
No.
Name
Description
Values