beautypg.com

Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual

Page 228

background image

Publication 1756-UM522B-EN-P - February 2003

B-148 1756-DMD30 Specific Information

2163

CML Ref Rate
Controls the current reference ramp block within the PMI
processor. Leave at default for most applications, which sets
the rate equal to parameter 354[Curr Rate Limit].

Default:
Min:
Max:
Type:
File:
Group:

4095
1
4095
Linkable, Read-Write, 16-bit Integer
DPS/PMI
Motor Data

2180

Motor NP RPM
Set to the motor nameplate rated RPM.

Units:
Default:
Min:
Max:
Type:
File:
Group:

RPM
1750
1
30000
Non-Linkable, Read-Write, 16-bit Integer
Torque Control
Current

2181

Overspd Trip Pt
Set the overspeed trip point for overspeed detection in the PMI
processor.

Units:
Default:
Min:
Max:
Type:
File:
Group:

RPM
2000
1
30000
Non-Linkable, Read-Write, 16-bit Integer
DPS/PMI
Motor Data

2182

Motor NP FLA
Set to the motor nameplate full load amps.

Units:
Default:
Min:
Max:
Type:
File:
Group:

Amps
1
1
3276.7
Non-Linkable, Read-Write, 16-bit Integer
DPS/PMI
Motor Data

2183

Motor NP Volts
Set to the motor nameplate rated volts.

Units:
Default:
Min:
Max:
Type:
File:
Group:

Volt
1
1
32767
Non-Linkable, Read-Write, 16-bit Integer
DPS/PMI
Motor Data

2184

PMI Curr Lim
Provides positive and negative current limit values within the
PMI processor. If this value is les than parameter 120[Current
PosLimit] and the absolute value of parameter 119 [Current
NegLimit], this value will set both the positive and negative
actual current limits.

Units:
Default:
Min:
Max:
Type:
File:
Group:

%
100
100
400
Non-Linkable, Read-Write, 16-bit Integer
DPS/PMI
Motor Data

2185

Hot Field Curr
Set to the Hot Amps value on the motor nameplate.

Units:
Default:
Min:
Max:
Type:
File:
Group:

Amps
0.10
0.01
327.67
Non-Linkable, Read-Write, 16-bit Integer
Speed Control
Regulator

No.

Name
Description

Values

This manual is related to the following products: