Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual
Page 318
![background image](/manuals/579192/318/background.png)
Publication 1756-UM522B-EN-P - February 2003
C-66 1756-DMF30 Specific Information
1164
SL Buf Real Tx01
Provides floating point (real) data for Direct Transmit word 1, if
the data type for word 1 (indicated in parameter 1160 [Tx Buf
Data Type]) is real.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
SynchLink
Buffered DataOut
1165
SL Buf Int Tx02
Provides integer data for Direct Transmit word 2, if the data
type for word 2 (indicated in parameter 1160 [Tx Buf Data
Type]) is integer.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-Bit Integer
SynchLink
Buffered DataOut
1166
SL Buf Real Tx02
Provides floating point (real) data for Direct Transmit word 2, if
the data type for word 2 (indicated in parameter 1160 [Tx Buf
Data Type]) is real.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
SynchLink
Buffered DataOut
1167
SL Buf Int Tx03
Provides integer data for Direct Transmit word 3, if the data
type for word 3 (indicated in parameter 1160 [Tx Buf Data
Type]) is integer.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-Bit Integer
SynchLink
Buffered DataOut
1168
SL Buf Real Tx03
Provides floating point (real) data for Direct Transmit word 3, if
the data type for word 3 (indicated in parameter 1160 [Tx Buf
Data Type]) is real.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
SynchLink
Buffered DataOut
1169
SL Buf Int Tx04
Provides integer data for Direct Transmit word 4, if the data
type for word 4 (indicated in parameter 1160 [Tx Buf Data
Type]) is integer.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-Bit Integer
SynchLink
Buffered DataOut
1170
SL Buf Real Tx04
Provides floating point (real) data for Direct Transmit word 4, if
the data type for word 4 (indicated in parameter 1160 [Tx Buf
Data Type]) is real.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
SynchLink
Buffered DataOut
1171
SL Buf Int Tx05
Provides integer data for Direct Transmit word 5, if the data
type for word 5 (indicated in parameter 1160 [Tx Buf Data
Type]) is integer.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-Bit Integer
SynchLink
Buffered DataOut
No.
Name
Description
Values