Rockwell Automation 1336T FORCE Series B User Manual
Page 186
Chapter 5
Programming Parameters
5–60
CP Operating Options
[CP Options]
Parameter Number
227
Parameter Type
Sink
Display Units
Bits
Drive Units
None
Factory Default
0000 0000 0000 0000
Minimum Value
0000 0000 0000 0000
Maximum Value
0000 0000 0011 0000
For proper operation, bits 0 to 6 must be
left at zero.
If bit 7 = 0, this allows the motor to coast to
a stop after the flux test is completed.
If bit 7 = 1, this brings the motor to a con-
trolled stop after the flux test is completed.
Parameter Number
228
Parameter Type
Sink
Display Units
x.x HP
Drive Units
Display units x 10
Factory Default
30.0 HP
Minimum Value
1.0 HP
Maximum Value
HP
Base Motor Speed
[Base Motor Speed]
Motor Nameplate Horsepower
[Base Motor HP]
Parameter Number
229
Parameter Type
Sink
Display Units
x RPM
Drive Units
x
Factory Default
1,750 RPM
Minimum Value
1 RPM
Maximum Value
15,000 RPM
Motor Nameplate AMPS
[Base Motor Curr]
Parameter Number
230
Parameter Type
Sink
Display Units
x.x amps
Drive Units
Display units x 10
Factory Default
0.2 amps
Minimum Value
0.1 amps
Maximum Value
Based on parameter 220
Drive nameplate current rating of the
motor. Used for current reference scaling
and current processor feedback scaling.
User entered value of nameplate motor
horsepower. The drive uses this informa-
tion in the Dynamic Brake Resistor
temperature calculation.
User entered value of nameplate motor
speed in RPM. The drive uses this
information to convert motor velocity RPM
to/from drive per unit.
Motor Nameplate VOLTS
[Base Motor Volt]
Parameter Number
231
Parameter Type
Sink
Display Units
x Volt
Drive Units
None
Factory Default
460 volt
Minimum Value
75 volt
Maximum Value
575 volt
Motor Nameplate Frequency
[Base Motor Freq]
Parameter Number
232
Parameter Type
Sink
Display Units
x.x Hz
Drive Units
display units x 10
Factory Default
60 Hz
Minimum Value
1 Hz
Maximum Value
250 Hz
Drive nameplate voltage rating of the
motor.
Total number of motor poles in motor.
Motor Nameplate Poles
[Motor Poles]
Parameter Number
233
Parameter Type
Sink
Display Units
x poles
Drive Units
None
Factory Default
4 poles
Minimum Value
2 poles
Maximum Value
40 poles
Motor Inertia
[Motor Inertia]
Parameter Number
234
Parameter Type
Sink
Display Units
x.xx Sec
Drive Units
Display units x 100
Factory Default
0.60 Sec
Minimum Value
0.01 Sec
Maximum Value
655 Sec
Time taken to accelerate
an uncoupled motor from zero to base
speed at rated torque.
Drive nameplate frequency rating of the
motor.