Programming Parameters

5–34

Process Trim Reference
[Proc Trim Ref]

Process Trim Feedback
[Proc Trim Fdbk]

Process Trim Select
[Proc Trim Sel]

Parameter Number

29

Parameter Type

Sink

Display Units

Bits

Drive Units

None

Factory Default

0000 0000 0000 0000

Minimum Value

0000 0000 0000 0000

Maximum Value

0000 0000 0011 1111

Enums:

Parameter Number

28

Parameter Type

Sink

Display Units

+/– x.x%

Drive Units

4096 = 100% trim

Factory Default

+ 0.0%

Minimum Value

– 800.0%

Maximum Value

+ 800.0%

Process Trim Filter Bandwidth
[Proc Trim Fltr W]

Parameter Number

30

Parameter Type

Sink

Display Units

x radians/sec

Drive Units

1 = radians/sec

Factory Default

0 radians/sec

Minimum Value

0 radians/sec

Maximum Value

240 radians/sec

Parameter Number

31

Parameter Type

Sink

Display Units

+/– x.x%

Drive Units

4096 = 100.0% preload

Factory Default

+0.0%

Minimum Value

–800.0%

Maximum Value

+800.0%

Parameter Number

27

Parameter Type

Sink

Display Units

+/– x.x%

Drive Units

4096 = 100% trim

Factory Default

+0.0%

Minimum Value

–800.0%

Maximum Value

+800.0%

Process Trim Data
[Proc Trim Data]

This is the reference input value for pro-
cess trim. The Process Trim Output is up-
dated based on the value of this input.

This is the feedback input value for pro-
cess trim. The Process Trim Output pa-
rameter is updated based on the value of
this input.

This is a bit coded word of data containing
several selection options for the process
trim regulator as follows:

Bit 0

Trim the Velocity Reference

Bit 1

Trim the Torque Reference

Bit 2

Select Velocity Inputs

Bit 3

Set Output Option

Bit 4

Preset Integrator Option

Bit 5

Force ON Trim Limit option

This parameter is used to preset the output
of the process trim regulator when either
the “Set Output Option” or “Preset Integra-
tor Option” is selected in parameter 29.

This parameter determines the bandwidth
of a single pole filter used with the error
input for process trim. The output of this
filter is used as the input to the process
trim regulator.

Process Trim KI Gain
[Proc Trim Ki]

Parameter Number

32

Parameter Type

Sink

Display Units

x.xxx

Drive Units

4096 = 1.000 Ki gain

Factory Default

1.000

Minimum Value

0.000

Maximum Value

16.000

This parameter controls the integral gain of
the process trim regulator. If process trim
equals 1.0, then the process trim PI regula-
tor output will equal 1 pu in 1 second, for 1
pu process trim error.