Rockwell Automation 1336T FORCE Series B User Manual
Page 131
![background image](/manuals/578410/131/background.png)
Chapter 5
Programming Parameters
5–5
Table 5.A – 1336T Numerical Parameter Table (Cont.)
86
87
88
89
90
91
92
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
117
118
119
120
121
122
123
125
126
127
128
129
CP Fault Configuration
CP Warning Configuration Select
VP Fault Configuration Select
VP Warning Configuration Select
Absolute Overspeed Threshold
Stall Delay
Motor Overload Limit
Service Factor
Motor Overload Speed 1
Motor Overload Speed 2
Minimum Overload Limit
Fault Testpoint Data
Fault Testpoint Select
Velocity Reference 1 LOW (FRACTION)
Velocity Reference 1 HI (WHOLE, 32 bit)
Velocity Scale Factor 1
Velocity Reference 2 LOW (FRACTION)
Velocity Reference 2 HI (WHOLE, 32 bit)
Velocity Scale Factor 2
Velocity Trim LOW
Velocity Trim HI (32 bit)
Velocity Reference Testpoint Data LOW
Velocity Reference Testpoint Data HI
Velocity Reference Testpoint Select
Jog Speed 1
Jog Speed 2
Preset Speed 1
Preset Speed 2
Preset Speed 3
Preset Speed 4
Preset Speed 5
Accel Time
Decel Time
Reverse Motor Speed Limit
Forward Motor Speed Limit
Maximum Reverse Speed Trim
Param No.
Parameter Name (Element)
Group
File (File No.)
Fault Select/Status
Fault Setup
Fault Select/Status
Fault Select/Status
Fault Setup
Fault Select/Status
Fault Select/Status
Fault Setup
Fault Select/Status
Fault Select/Status
Fault Setup
Fault Select/Status
Fault Setup
Fault Setup
Fault Setup
Motor Overload
Motor Overload
Limits
Fault Setup
Motor Overload
Fault Setup
Motor Overload
Fault Setup
Motor Overload
Testpoints
Testpoints
Velocity Ref
Velocity Ref
Velocity Ref
Velocity Ref
Velocity Ref
Velocity Ref
Velocity Ref
Velocity Ref
Velocity Ref
Testpoints
Velocity Ref
Testpoints
Velocity Ref
Testpoints
Velocity Ref
Velocity Ref
Velocity Ref
Velocity Ref
Velocity Ref
Velocity Ref
Velocity Ref
*
*
Velocity Ref
Limits
Velocity Ref
Velocity Ref
Communications I/O (2)
Startup (1)
Diagnostics (4)
Communications I/O (2)
Startup (1)
Diagnostics (4)
Communications I/O (2)
Startup (1)
Diagnostics (4)
Communications I/O (2)
Startup (1)
Diagnostics (4)
Startup (1)
Startup (1)
Startup (1)
Diagnostics (4)
Diagnostics (4)
Startup (1)
Startup (1)
Diagnostics (4)
Startup (1)
Diagnostics (4)
Startup (1)
Diagnostics (4)
Diagnostics (4)
Diagnostics (4)
Velocity Torque (3)
Velocity Torque (3)
Velocity Torque (3)
Velocity Torque (3)
Velocity Torque (3)
Velocity Torque (3)
Velocity Torque (3)
Velocity Torque (3)
Velocity Torque (3)
Diagnostics (4)
Velocity Torque (3)
Diagnostics (4)
Velocity Torque (3)
Diagnostics (4)
Velocity Torque (3)
Velocity Torque (3)
Velocity Torque (3)
Velocity Torque (3)
Velocity Torque (3)
Velocity Torque (3)
Velocity Torque (3)
*
*
Velocity Torque (3)
Startup (1)
Velocity Torque (3)
Velocity Torque (3)
85
VP Configurable Warning Status
Fault Select/Status
Fault Select/Status
Communications I/O (2)
Diagnostics (4)
Param Descrpt.
See Page 5–43
See Page 5–43
See Page 5–43
See Page 5–43
See Page 5–43
See Page 5–44
See Page 5–44
See Page 5–44
See Page 5–44
See Page 5–44
See Page 5–44
See Page 5–44
See Page 5–44
See Page 5–44
See Page 5–45
See Page 5–45
See Page 5–45
See Page 5–45
See Page 5–45
See Page 5–45
See Page 5–45
See Page 5–45
See Page 5–45
See Page 5–45
See Page 5–45
See Page 5–45
See Page 5–46
See Page 5–46
See Page 5–46
See Page 5–46
See Page 5–46
See Page 5–47
See Page 5–47
See Page 5–47
See Page 5–47
See Page 5–47
See Page 5–47
See Page 5–47
See Page 5–47
See Page 5–47
See Page 5–48
See Page 5–48
See Page 5–48
See Page 5–48
See Page 5–48
See Page 5–48
See Page 5–48
See Page 5–49
See Page 5–49
See Page 5–49
See Page 5–49
See Page 5–49
See Page 5–49
See Page 5–49
See Page 5–49
* Can be viewed only with PLC Comm Board installed