Chapter 5
Programming Parameters
5–44
CP Warning/None Configuration Select
[CP Warn Select]
Parameter Number
87
Parameter Type
Sink
Display Units
Bits
Drive Units
None
Factory Default
0000 0000 0001 1111
Minimum Value
0000 0000 0000 0000
Maximum Value
1111 1111 1111 1111
Enums:
This word parameter determines conditions
detected by the Current Processor (CP)
that will be reported as either a drive fault
or drive warning condition. Each configu-
ration bit matches the bit definition of Pa-
rameter 82, 84 and 86. When a bit is set to
“1”, the corresponding condition in the
Drive will be reported as a FAULT, other-
wise the condition is reported as a
WARNING.
VP Fault/Warning Configuration Select
[VP Fault Select]
Parameter Number
88
Parameter Type
Sink
Display Units
Bits
Drive Units
None
Factory Default
1111 1111 1111 1111
Minimum Value
0000 0000 0000 0000
Maximum Value
1111 1111 1111 1111
Enums:
This word parameter determines conditions
detected by the Velocity Processor (VP)
that will be reported as either a drive
FAULT or drive WARNING condition. Each
configuration bit matches the bit definitions
of Parameters 83, 85 and 89. When a bit
is set to “1” the corresponding condition in
the Drive will be reported as a FAULT,
otherwise the condition is reported as a
WARNING.
Bit
Condition
0
Bus Ridethrough Timeout
1
Bus Precharge Timeout
2
Bus Drop (150 volts)
3
Bus Undervoltage
4
Bus Drop Cycles
5
Fast Flux Up Current < 50%
Bit
Condition
0
Encoder Feedback Loss
1
Inverter Overemp Pending
2
Motor Overtemperature Tripped
3
Motor Overload Pending (I
2
T)
4
Motor Overload Trip (I
2
T)
5
Motor Stalled
6
External Fault
7
RMS Fault
8
Reserved, Leave Zero
Bit
Condition
9
Parameter Limit
10
Math Limit
11
Dynamic brake overtemp
12
AC Motor Contactor Failure
13
Inverter Overload Pending (IT)
14
Drive to Drive Fault
15
Inverter Overload Trip (IT)
VP Warning/None Configuration Select
[VP Warn Select]
Parameter Number
89
Parameter Type
Sink
Display Units
Bits
Drive Units
None
Factory Default
1111 1111 1111 1111
Minimum Value
0000 0000 0000 0000
Maximum Value
1111 1111 1111 1111
Enum:
This parameter determines conditions de-
tected by the Velocity Processor (VP) that
will be reported as either a drive FAULT or
WARNING or not reported (ignored). Each
configuration bit matches the bit definitions
of Parameters 83, 85 and 88. When a bit
is set to “1”, the corresponding condition in
the Drive will be reported as configured by
parameter 88. If the bit is set to “0”, the
condition is not reported.
Bit
Condition
0
Encoder Feedback Loss
1
Inverter Overtemp Pending
2
Motor Overtemperature Tripped
3
Motor Overload Pending (I
2
T)
4
Motor Overload Trip (I
2
T)
5
Motor Stalled
6
External Fault
7
RMS Fault
Bit
Condition
8
Not Used
9
Parameter Limit
10
Math Limit
11
Dynamic brake overtemp
12
AC Motor Contactor Failure
13
Inverter Overload Pending (IT)
14
Drive to Drive Fault
15
Inverter Overload Foldback (IT)