beautypg.com

Commissioning – Lenze ECSCMxxx User Manual

Page 156

background image

Commissioning

Setting of homing parameters
Example: Reference search with linear positioning axis

6

l

156

EDBCSXM064 EN 11.0

6.13.4

Example: Reference search with linear positioning axis

Settings for homing mode 13

ƒ

Set homing mode 13 with C3010 = 13.

ƒ

The negative hardware limit switch is to be used as reference switch at the same
time:
– Connect hardware limit switch in parallel with X6/DI3 and X6/DI4. (For terminal

assignment see

^ 68)

– Set C0114/3 and C0114/4 = 1 (LOW level is active).

ƒ

Set travelling speed with C0935.

ƒ

Set acceleration/deceleration with C0936.

ƒ

Define target position as offset to the home position via C3011.

1

4

0

3

2

C3011

100

200

300

400

500

600

5

ECSXA435

Fig. 6−28

Homing in mode 3, negative hardware limit switch as reference switch

0 Negative hardware limit switch

1 Travel towards reference switch

2 Travel via the defined offset (C3011) towards target position

3 Positive hardware limit switch

4 Zero pulse (zero position of the position encoder)

5 Target position