beautypg.com

13 setting of homing parameters, 1 homing parameters, Homing parameters – Lenze ECSCMxxx User Manual

Page 143: Commissioning

background image

Commissioning

Setting of homing parameters

Homing parameters

6

l

143

EDBCSXM064 EN 11.0

6.13

Setting of homing parameters

During homing the drive traverses in a preselected mode (C3010). While doing so, the zero
position (reference) is detected by means of a reference mark and transmitted to the drive
control. All position data refer to this reference.

The GDC parameter menu includes the codes for setting the homing parameters (e.g.
homing mode, speed, offsets) under Motion

W Homing.

ECSXA537

Fig. 6−15

GDC view: Short setup, entry of homing parameters

6.13.1

Homing parameters

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0935 L_REF1 speed

100

Traversing speed of homing

^ 143

1

{1 rpm}

16000

C0936 L_REF1 Ti

1.0

Deceleration time (T

i

) of homing

^ 143

0.01

{0.01 s}

650.00

C3008 HomeMlim

10.0

Torque limit value for homing
mode C3010 = 16 or 17
(100.00 % = maximum torque
from C0057)

^ 153

0.00

{0.01 %}

100.00

C3009 TimeHome

Mlim

100

Duration for detecting the
mechanical limit stop for homing
mode C3010 = 16 or 17

^ 153

0

{1 ms}

65535

This manual is related to the following products: