beautypg.com

2 opening the brake, Opening the brake, Commissioning – Lenze ECSCMxxx User Manual

Page 108

background image

Commissioning

Holding brake configuration
Opening the brake

6

l

108

EDBCSXM064 EN 11.0

6.6.2

Opening the brake

t

t

t

t

t

t

t

0

1



‚

ƒ

C0244

C0196

CtrlWord.Bit7

CtrlWord.Bit9

QSP

NSet

MAct

C0244

X6/B+

 Use control bit 7 = 1 (TRUE) to enable the

controller. The control bit 9 is set to 0 (FALSE) at
the same time (controller inhibit (CINH) is
deactivated) and the torque defined in C0244 is
created. This happens within the brake opening
time set in C0196.

‚ As soon as the torque (Mact) has reached the

value in C0244, the brake is opened.

ƒ If the brake is opened via the digital output

X6/B+, the following happens after the brake
opening time has elapsed (C0196)

l

Quick stop (QSP) is cancelled.

l

Setpoint integrator is enabled.

ECSXA519

CtrlWord.Bit7

Controller enable (control bit 7)

CtrlWord.Bit9

Controller inhibit (control bit 9)

Mact

Actual torque

X6/B+

Digital output X6/B+

QSP

Quick stop (QSP)

Nset

Setpoint speed

0

Brake is closed

1

Brake is open

This manual is related to the following products: